AUTOMATIC TRANSMISSION SYSTEM (for 2TR-FE), Diagnostic DTC:P2769, P2770

DTC Code DTC Name
P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)
P2770 Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)

DESCRIPTION

Shift solenoid valve SL is turned on and off by signals from the ECM to control the hydraulic pressure acting on the lock-up relay valve, which then controls operation of the lock-up clutch.

DTC No. DTC Detection Condition Trouble Area
P2769 ECM detects a short in the shift solenoid valve SL circuit when the shift solenoid valve SL is operated (2 trip detection logic).
  • Short in shift solenoid valve SL circuit

  • Shift solenoid valve SL

  • ECM

P2770 ECM detects an open in the shift solenoid valve SL circuit when the shift solenoid valve SL is not operated (2 trip detection logic).
  • Open in shift solenoid valve SL circuit

  • Shift solenoid valve SL

  • ECM

Fail-safe function:

If the ECM detects a malfunction, it turns shift solenoid valve SL off.

MONITOR DESCRIPTION

Based on the signals from the throttle position sensor, the air flow meter and the crankshaft position sensor, the ECM sends a signal to shift solenoid valve SL to regulate the hydraulic pressure and provide smoother torque converter engagement. Shift solenoid valve SL responds to commands from the ECM. The valve controls the lock-up relay valve to perform the torque-converter lock-up function. If the ECM detects an open or short in the shift solenoid valve SL circuit, it will illuminate the MIL and store the DTC.

WIRING DIAGRAM

B007P2OE14

INSPECTION PROCEDURE

Note

Perform registration and/or initialization when parts related to the automatic transmission are replaced Click here.

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)


    1. B007TU8E02
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Wire)

      Disconnect the transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (SL) - Body ground 20°C (68°F) 11 to 15 Ω

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. B007U51E09
      Text in Illustration
      *a

      Front view of wire harness connector

      (to ECM)

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D116-40 (SL) - Body ground 20°C (68°F) 11 to 15 Ω

    NG
    OK
  3. INSPECT SHIFT SOLENOID VALVE SL


    1. B007QOSE01
      Text in Illustration
      *1 Shift Solenoid Valve SL

      Remove shift solenoid valve SL Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve SL connector terminal - Shift solenoid valve SL body 20°C (68°F) 11 to 15 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) → Shift solenoid valve SL connector

      • Battery negative (-) → Shift solenoid valve SL body

      Valve moves and makes an operating noise

    NG
    OK