GENERATOR (w/ Dual VVT-i) REMOVAL


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  3. REMOVE FAN AND GENERATOR V BELT

    Click here

  4. REMOVE GENERATOR ASSEMBLY


    1. B007Q9J

      Disconnect the generator connector.

    2. Remove the terminal cap.

    3. Remove the nut and disconnect the wire harness from terminal B.

    4. Remove the bolt and disconnect the wire harness clamp.

    5. B007USG

      Remove the 3 bolts and generator assembly.