SFI SYSTEM (w/o Secondary Air Injection System), Diagnostic DTC:P0135

DTC Code DTC Name
P0135 Oxygen Sensor Heater Circuit (Bank 1 Sensor 1)

DESCRIPTION

Refer to DTC P0130 Click here.

DTC No. DTC Detection Condition Trouble Area
P0135 Open or short in the heater circuit of the oxygen sensor for 0.5 seconds or more (1 trip detection logic).
  • Open or short in heater circuit of oxygen sensor

  • Heated oxygen sensor

  • ECM

WIRING DIAGRAM

Refer to DTC P0130 Click here.

INSPECTION PROCEDURE

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

Tech Tips

Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

PROCEDURE


  1. INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)


    1. Inspect the heated oxygen sensor Click here.


    NG
    OK
  2. CHECK TERMINAL VOLTAGE (+B OF HEATED OXYGEN SENSOR)

    B007VTFE12
    Text in Illustration
    *a

    Front view of wire harness connector

    (to Heated Oxygen Sensor)


    1. Disconnect the heated oxygen sensor connector.

    2. Turn the ignition switch to ON.

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      D34-2 (+B) - Body ground Ignition switch ON 11 to 14 V

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)


    1. Disconnect the heated oxygen sensor connector.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D34-1 (HT1A) - D97-104 (HA1A) Always Below 1 Ω
      D34-1 (HT1A) or D97-104 (HA1A) - Body ground Always 10 kΩ or higher

    NG
    OK
  4. CHECK WHETHER DTC OUTPUT RECURS


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the intelligent tester on.

    4. Clear the DTCs Click here.

    5. Turn the ignition switch off and wait for at least 30 seconds.

    6. Turn the ignition switch to ON.

    7. Wait 5 seconds or more.

    8. Read the DTCs.

      Result
      Result Proceed to
      No DTC is output A
      DTC P0135 is output B

    B
    A
  5. CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - NO. 1 INTEGRATION RELAY)


    1. Disconnect the heated oxygen sensor connector.

    2. Remove the No. 1 integration relay from the No. 1 engine room relay block.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D34-2 (+B) - 10A-8 Always Below 1 Ω
      D34-2 (+B) or 10A-8 - Body ground Always 10 kΩ or higher

    NG
    OK