| DTC Code | DTC Name |
|---|---|
| P071512 | Input/Turbine Speed Sensor "A" Circuit Short to Battery |
| P071514 | Input/Turbine Speed Sensor "A" Circuit Short to Ground or Open |
| P071531 | Input/Turbine Speed Sensor "A" No Signal |
DESCRIPTION
The ECM receives a signal from the transmission revolution sensor (NT) installed to the continuously variable transaxle to control the lock-up engagement pressure and forward and reverse clutch pressure.
The transmission revolution sensor (NT) detects the input turbine speed and sends a signal to the ECM.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P071512 | Input/Turbine Speed Sensor "A" Circuit Short to Battery | There is no malfunction in transmission revolution sensor (NT) signals, and the transmission revolution sensor (NT) output voltage is higher than 1.8 V for 2 seconds (1 trip detection logic). |
|
Comes on | DTC stored | SAE Code: P07C0 |
| P071514 | Input/Turbine Speed Sensor "A" Circuit Short to Ground or Open | There is no malfunction in transmission revolution sensor (NT) signals, and the transmission revolution sensor (NT) output voltage is less than 0.2 V for 2 seconds (1 trip detection logic). |
|
Comes on | DTC stored | SAE Code: P07BF |
| P071531 | Input/Turbine Speed Sensor "A" No Signal | All of the following conditions are met (1 trip detection logic):
|
|
Comes on | DTC stored | SAE Code: P0717 |
MONITOR DESCRIPTION
The transmission revolution sensor (NT) is used to detect the input turbine speed. The ECM determines the necessary gear ratio based on a comparison of the transmission revolution sensor (NT) (input turbine speed) and transmission revolution sensor (NOUT) (output shaft speed) signals.
When the output shaft speed is higher than the expected value and the input turbine speed is less than 300 rpm while driving with the shift lever in D, the ECM will determine that the transmission revolution sensor (NT) is malfunctioning, illuminate the MIL and store a DTC.
WIRING DIAGRAM
| *a | Transmission Revolution Sensor (NT) |
| *b | Continuously Variable Transmission Assembly (Transmission Wire) |
CAUTION / NOTICE / HINT
Note
Perform initialization after replacing any parts related to the continuously variable transaxle system.
Check that no DTCs are stored after performing initialization.
Tech Tips
After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Drive the vehicle for 2 seconds or more at 7 km/h (4.375 mph) or more with the shift lever in D.
Check for DTCs again.
PROCEDURE
READ VALUE USING GTS (NT SENSOR SPEED AND NT SENSOR VOLTAGE)
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Transmission / Data List.
| Tester Display |
|---|
| NT Sensor Speed |
| NT Sensor Voltage |
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| NT Sensor Speed | Input turbine speed (NT) | Min.: 0 rpm Max.: 12750 rpm |
|
Data is displayed in increments of 50 rpm. |
| NT Sensor Voltage | Transmission revolution sensor (NT) output voltage | Min.: 0.000 V Max.: 4.999 V |
0.2 to 1.8 V: Engine idling (Vehicle stopped with shift lever in P or N) | - |
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
REPLACE ECM Click here |
| A |
|
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
Disconnect the C40 transmission wire connector.
Disconnect the C62 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Connect the C62 ECM connector.
Connect the C40 transmission wire connector.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM) |
| OK |
|
CHECK ECM
| *a | Front view of wire harness connector (to Transmission Wire) |
Disconnect the transmission wire connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Turn the ignition switch off.
Connect the transmission wire connector.
| *a | Component without harness connected (ECM) |
Disconnect the C62 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE ECM Click here |
| OK |
|
REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
Replace the continuously variable transaxle assembly.
When Not Using the Engine Support Bridge
When Using the Engine Support Bridge
| Result | ||
|---|---|---|
|
| NEXT |
|
PERFORM INITIALIZATION Click here |
REPLACE ECM
Replace the ECM.
| Result | ||
|---|---|---|
|
| NEXT |
|
PERFORM INITIALIZATION Click here |
REPLACE ECM
Replace the ECM.
| Result | ||
|---|---|---|
|
| NEXT |
|
PERFORM INITIALIZATION Click here |