GLOW PLUG CONTROLLER INSTALLATION


  1. INSTALL NO. 1 GLOW PLUG CONTROLLER BRACKET


    1. Install the No. 1 glow plug controller bracket to the glow plug controller with the 2 screws.

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
  2. INSTALL GLOW PLUG CONTROLLER ASSEMBLY


    1. Connect the 4 connectors.

    2. Install the glow plug controller assembly with the 2 bolts.

      Torque:
      20 N*m  { 204 kgf*cm, 15 ft.*lbf }
  3. INSTALL NO. 2 AIR CLEANER INLET


    1. A01IU27

      Install the No. 2 air cleaner inlet with the bolt.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
  4. INSTALL NO. 1 AIR CLEANER INLET


    1. A01IRC4

      Attach the 2 claws to install the No. 1 air cleaner inlet.

    2. Install the clip.

  5. INSTALL AIR CLEANER CASE SUB-ASSEMBLY


    1. Install the air cleaner case with the 3 bolts.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
  6. INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

  7. INSTALL AIR CLEANER CAP SUB-ASSEMBLY


    1. Connect the air cleaner hose assembly to the turbocharger sub-assembly, and slide the clamp secure it.

    2. A01INV0E02
      Text in Illustration
      *a Upper

      Attach the 4 clamps to install the air cleaner cap sub-assembly.

    3. Connect the PCV hose to the cylinder head cover sub-assembly, and slide the clamp secure it.

    4. Attach the clamp and connect the mass air flow meter connector.

  8. INSTALL BATTERY

  9. INSTALL BATTERY INSULATOR

  10. INSTALL BATTERY CLAMP SUB-ASSEMBLY


    1. Attach the hook of the battery clamp sub-assembly to the battery carrier.

    2. Partially tighten the nut and temporarily install the bolt.

    3. Adjust the battery clamp sub-assembly position.

    4. Tighten the nut and bolt.

      Torque:
      for bolt
      17 N*m  { 168 kgf*cm, 12 ft.*lbf }
      for nut
      3.5 N*m  { 36 kgf*cm, 31 in.*lbf }
  11. CONNECT CABLE TO POSITIVE BATTERY TERMINAL

  12. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.