ECM INSTALLATION


  1. INSTALL ECM


    1. Install the 2 brackets to the ECM with the 4 screws.

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
    2. Install the ECM with bracket with the 2 bolts.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    3. A01IPY2

      Connect the 2 ECM connectors and lower the 2 levers.

      Note


      • When connecting the connector, make sure that dirt, water or other foreign matter is not stuck between the connector and ECM.

      • Make sure that the 2 levers are securely lowered.

  2. INSTALL NO. 2 AIR CLEANER INLET


    1. Install the No. 2 air cleaner inlet with the bolt.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
  3. INSTALL NO. 1 AIR CLEANER INLET


    1. Attach the 2 claws and install the No. 1 air cleaner inlet.

    2. Install the clip.

  4. INSTALL AIR CLEANER CASE SUB-ASSEMBLY


    1. Install the air cleaner case with the 3 bolts.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
  5. INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

  6. INSTALL AIR CLEANER CAP SUB-ASSEMBLY


    1. A01INV0E02
      Text in Illustration
      *a Upper

      Connect the air cleaner hose assembly to the turbocharger, and slide the clamp secure it.

      Tech Tips

      The direction of the hose clamp is indicated in the illustration.

    2. Attach the 4 clamps to install the air cleaner cap sub-assembly.

    3. Connect the PCV hose to the cylinder head cover sub-assembly, and slide the clamp secure it.

    4. Attach the clamp and connect the mass air flow meter connector.

  7. INSTALL RADIATOR SUPPORT OPENING COVER


    1. Attach the 4 hooks to install the radiator support opening cover.

    2. Install the 3 clips.

  8. INSTALL NO. 1 ENGINE COVER


    1. A01INMI

      Attach the 4 clips to install the No. 1 engine cover.

  9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  10. PERFORM REGISTRATION

    Click here

  11. PERFORM INITIALIZATION

    Click here

  12. PERFORM THROTTLE VALVE FULLY CLOSED POSITION LEARNING

    Tech Tips

    Be sure to turn off the ignition switch before performing this inspection.


    1. Turn the ignition switch to ON.

    2. Turn the ignition switch off and wait 10 seconds.

      Tech Tips

      The fully closed position of the diesel throttle valve is learned when the ignition switch is turned off.