SFI SYSTEM ACIS Control Circuit

DESCRIPTION

This circuit opens and closes the Intake Air Control Valve (IACV) in response to the engine load in order to increase the intake efficiency (ACIS: Acoustic Control Induction System).

A01IR9LE05
Text in Illustration
*a Intake Air Control Valve Open *b Intake Air Control Valve Closed

WIRING DIAGRAM

Refer to DTC P0660 Click here.

INSPECTION PROCEDURE

Note

Inspect the fuses of circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. PERFORM ACTIVE TEST USING GTS (OPERATE VSV FOR ACIS)

    A01IUBQE02
    Text in Illustration
    *1 Air
    *2 Port F
    *3 Port E
    *4 Air Filter
    *a VSV is ON
    *b VSV is OFF

    1. Disconnect the vacuum hose from port F of the vacuum switching valve (for ACIS).

    2. Connect the GTS to the DLC3.

    3. Start the engine.

    4. Enter the following menus: Powertrain / Engine and ECT / Active Test / Active the VSV for Intake Control.

    5. Operate the VSV for ACIS.

    6. Check the VSV air flow when switching the VSV on and off.

      OK
      Test Condition Specified Condition
      VSV is ON Air from port E flows out through port F
      VSV is OFF Air from port E flows out through air filter

    NG
    OK
  2. CHECK VACUUM HOSES (VSV FOR ACIS - INTAKE AIR CONTROL VALVE, INTAKE MANIFOLD)


    1. Check the vacuum hoses Click here.


    NG
    OK
  3. INSPECT INTAKE MANIFOLD (INTAKE AIR CONTROL VALVE)


    1. Inspect the intake air control valve Click here.


    NG
    OK
  4. INSPECT VSV FOR ACIS


    1. Inspect the VSV for ACIS Click here.


    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (VSV FOR ACIS - ECM AND INTEGRATION RELAY)


    1. Disconnect the VSV for ACIS connector.

    2. Disconnect the ECM connector.

    3. Remove the integration relay from the engine room relay block.

    4. Disconnect the integration relay connector.

    5. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      C106-1 - C111-62 (ACIS) Always Below 1 Ω
      C106-2 - 1B-4 Always Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      C106-1 or C111-62 (ACIS) - Body ground Always 10 kΩ or higher
      C106-2 or 1B-4 - Body ground Always 10 kΩ or higher
    6. Reconnect the VSV for ACIS connector.

    7. Reconnect the ECM connector.

    8. Reconnect the integration relay connector.

    9. Install the integration relay.


    NG
    OK
  6. CHECK ECM POWER SOURCE CIRCUIT


    1. Check the ECM power source circuit Click here.


    NG
    OK