| DTC Code | DTC Name |
|---|---|
| P0A94-172 | DC / DC Converter Performance |
DESCRIPTION
For a description of the boost converter Click here.
If a malfunction occurs in the boost converter, the MG ECU detects it and transmits this information to the power management control ECU.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0A94-172 | Boost converter fail signal detection (overcurrent due to system malfunction) A malfunction is detected in any of the boost converter components (inverter, hybrid vehicle transmission assembly, MG ECU, etc.). (1 trip detection logic) |
|
WIRING DIAGRAM
Refer to the wiring diagram for DTC P0A1A-200 Click here.
Refer to the wiring diagram for DTC P0AA6-526 Click here.
Refer to the wiring diagram for DTC P324E-788 Click here.
Refer to the wiring diagram for DTC U0110-159 Click here.
INSPECTION PROCEDURE
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (READY) and wait for 5 seconds or more.
Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A94-172 only is output, or DTCs except the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| Relevant DTC | |
|---|---|
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-113, 128, 266, 267, 279, 284, 286, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808 | Drive Motor "A" Inverter Performance |
| P0A7A-122, 130, 322, 324, 325, 344, 517, 518, 809, 810, 811 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590 | DC / DC Converter Performance |
| P0AA6-526 | Hybrid Battery Voltage System Isolation Fault |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
Tech Tips
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0A94-172 may be output due to a malfunction which also causes DTCs in the preceding table to be output. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check connection condition of the low voltage connector of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.
| *A | for LHD | *B | for RHD |
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
Tech Tips
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| for RHD | |||||||||||||||||||||
|
Note
Turning the power switch on (IG) with the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK GENERATOR RESOLVER
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | ||||||||||||
|
||||||||||||
| for RHD | ||||||||||||
|
| Standard Resistance (Check for Short) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | ||||||||||||
|
||||||||||||
| for RHD | ||||||||||||
|
Reconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| NG |
|
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| for RHD | |||||||||||||||||||||
|
Note
Turning the power switch on (IG) with the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK MOTOR RESOLVER
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | ||||||||||||
|
||||||||||||
| for RHD | ||||||||||||
|
| Standard Resistance (Check for Short) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | ||||||||||||
|
||||||||||||
| for RHD | ||||||||||||
|
Reconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| NG |
|
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
for Type A:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
for Type B:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
| *1 | Generator Cable (Inverter with Converter Assembly Side) |
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected
| Specified Condition |
|---|
| T=8.0 N*m (82 kgf*cm, 71 in.*lbf) |
Note
Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Disconnect the generator cable from the inverter with converter assembly.
Check for arc marks at the terminals for the generator cable.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the generator cable to the inverter with converter assembly.
Install the inverter terminal cover.
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
for Type A:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
for Type B:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
| *1 | Motor Cable (Inverter with Converter Assembly Side) |
Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m (82 kgf*cm, 71 in.*lbf) |
Note
Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Disconnect the motor cable from the inverter with converter assembly.
Check for arc marks at the terminals for the motor cable.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable to the inverter with converter assembly.
Install the inverter terminal cover.
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MG1)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
for Type A:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
for Type B:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
| *1 | Motor Cable |
| *2 | Generator Cable |
Disconnect the generator cable and motor cable from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
| *1 | Shield Ground |
| *a | Generator Cable (Inverter with Converter Assembly Side) |
Check generator (MG1) for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
Tech Tips
If the generator (MG1) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | ||||||||||||
|
||||||||||||
| for RHD | ||||||||||||
|
Tech Tips
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68° F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C)
When checking for a short circuit between motor phases without using a milliohmmeter.
Note
The motor generates current when wheels are rotated by hand. Before performing the inspection, wrap the motor cable terminals with insulation tape.
Tech Tips
A short circuit between the motor phases can be checked simply without using a milliohmmeter.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Note
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Move the shift lever to N.
Lift up the vehicle.
Rotate the rear wheels in the same direction simultaneously by hand.
| Standard |
|---|
| Left and right wheels rotate smoothly (No short circuit between phases) |
Tech Tips
If a short circuit exists between the motor phases, the rear wheels do not rotate smoothly (some resistance is felt).
Lower the vehicle.
Move the shift lever to P.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | ||||||||||||
|
||||||||||||
| for RHD | ||||||||||||
|
Measure the resistance according to the value(s) in the table below.
Tech Tips
Perform this procedure only when checking for a short circuit between motor phases without using a milliohmmeter.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||
|
|||||||||
| for RHD | |||||||||
|
Connect the generator cable and motor cable.
Install the inverter terminal cover.
| NG |
|
| OK |
|
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MG2)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
for Type A:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
for Type B:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
| *1 | Motor Cable |
| *2 | Generator Cable |
Disconnect the generator cable and motor cable from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
| *1 | Shield Ground |
| *a | Motor Cable (Inverter with Converter Assembly Side) |
Check motor (MG2) for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
Tech Tips
If the motor (MG2) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | ||||||||||||
|
||||||||||||
| for RHD | ||||||||||||
|
Tech Tips
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68° F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C)
When checking for a short circuit between motor phases without using a milliohmmeter.
Note
The motor generates current when wheels are rotated by hand. Before performing the inspection, wrap the motor cable terminals with insulation tape.
Tech Tips
A short circuit between the motor phases can be checked simply without using a milliohmmeter.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Note
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Move the shift lever to N.
Lift up the vehicle.
Rotate the rear wheels in the same direction simultaneously by hand.
| Standard |
|---|
| Left and right wheels rotate smoothly (No short circuit between phases) |
Tech Tips
If a short circuit exists between the motor phases, the rear wheels do not rotate smoothly (some resistance is felt).
Lower the vehicle.
Move the shift lever to P.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | ||||||||||||
|
||||||||||||
| for RHD | ||||||||||||
|
Measure the resistance according to the value(s) in the table below.
Tech Tips
Perform this procedure only when checking for a short circuit between motor phases without using a milliohmmeter.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||
|
|||||||||
| for RHD | |||||||||
|
Connect the generator cable and motor cable.
Install the inverter terminal cover.
| NG |
|
| OK |
|
CHECK FUSE (IGCT NO. 4)
| *1 | No. 1 Engine Room Relay Block and Junction Block Assembly |
| *2 | IGCT NO. 4 Fuse |
Remove the IGCT NO. 4 fuse from the No. 1 engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Install the IGCT NO. 4 fuse.
| NG |
|
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||
|
|||||||||
| for RHD | |||||||||
|
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||
|
|||||||||
| for RHD | |||||||||
|
Note
Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| NG |
|
REPAIR OR REPLACE POWER SOURCE CIRCUIT |
| OK |
|
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A35 power management control ECU connector.
Disconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector (to Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||
| for RHD | |||||||||||||||||||||||||||
|
| Standard Resistance (Check for Short) | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||
| for RHD | |||||||||||||||||||||||||||
|
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||
| for RHD | |||||||||||||||||||||||||||
|
Note
Turning the power switch on (IG) with the power management control ECU and inverter with converter assembly connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Reconnect the A35 power management control ECU connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK POWER MANAGEMENT CONTROL ECU
Disconnect the A35 power management control ECU connector.
| *a | Component without harness connected (Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Reconnect the A35 power management control ECU connector.
| NG |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
Remove the hybrid vehicle transmission assembly Click here.
Check the connection condition of the generator resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
Check the connection condition of the motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
Install the hybrid vehicle transmission assembly.
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here
CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
Remove the hybrid vehicle transmission assembly Click here.
Check the connection condition of the generator resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Disconnect the F50 generator resolver connector.
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Generator Resolver) |
| *b | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| for RHD | |||||||||||||||||||||
|
| Standard Resistance (Check for Short) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| for RHD | |||||||||||||||||||||
|
Tech Tips
The generator resolver is not available as a supply part. If it requires replacement, replace the hybrid vehicle transmission assembly.
Reconnect the F50 generator resolver connector.
Reconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here
CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
Remove the hybrid vehicle transmission assembly Click here.
Check the connection condition of the motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Disconnect the F51 motor resolver connector.
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Motor Resolver) |
| *b | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| for RHD | |||||||||||||||||||||
|
| Standard Resistance (Check for Short) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| for RHD | |||||||||||||||||||||
|
Tech Tips
The motor resolver is not available as a supply part. If it requires replacement, replace the hybrid vehicle transmission assembly.
Reconnect the F51 motor resolver connector.
Reconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the hybrid vehicle transmission assembly Click here.
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m (82 kgf*cm, 71 in.*lbf) |
Note
Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Disconnect the generator cable from the hybrid vehicle transmission assembly.
Check for arc marks at the terminals for the generator cable.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the generator cable to the hybrid vehicle transmission assembly.
Install the hybrid vehicle transmission assembly.
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK GENERATOR CABLE
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the generator cable Click here.
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *1 | Shield ground | - | - |
| *a | Generator Cable (Inverter with Converter Assembly Side) |
*b | Generator Cable (Hybrid Vehicle Transmission Assembly Side) |
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | ||||||||||||
|
||||||||||||
| for RHD | ||||||||||||
|
Note
Wrap the terminal of the generator cable with insulating tape to prevent them from coming into contact with body ground.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| for RHD | |||||||||||||||||||||
|
Install the generator cable.
| NG |
|
REPLACE GENERATOR CABLE Click here |
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the hybrid vehicle transmission assembly Click here.
Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m (82 kgf*cm, 71 in.*lbf) |
Note
Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Disconnect the motor cable from the hybrid vehicle transmission assembly.
Check for arc marks at the terminals for the motor cable.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable to the hybrid vehicle transmission assembly.
Install the hybrid vehicle transmission assembly.
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK MOTOR CABLE
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the motor cable Click here.
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *1 | Shield ground | - | - |
| *a | Motor Cable (Inverter with Converter Assembly Side) |
*b | Motor Cable (Hybrid Vehicle Transmission Assembly Side) |
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | ||||||||||||
|
||||||||||||
| for RHD | ||||||||||||
|
Note
Wrap the terminal of the motor cable with insulating tape to prevent them from coming into contact with body ground.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| for RHD | |||||||||||||||||||||
|
Install the motor cable.
| NG |
|
REPLACE MOTOR CABLE Click here |
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT NO. 4 FUSE)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||
|
|||||||||
| for RHD | |||||||||
|
Reconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR Click here |
| OK |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY
| NEXT |
|
REPLACE FUSE (IGCT NO. 4)
REPAIR OR REPLACE HARNESS OR CONNECTOR
| NEXT |
|
REPLACE FUSE (IGCT NO. 4)