| DTC Code | DTC Name |
|---|---|
| P0A92-261 | Hybrid Generator Performance |
DESCRIPTION
For a description of generator (MG1) Click here.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0A92-261 | Generator magnetic force deterioration or same phase short circuit Magnetic force of the generator decreases or a coil short circuit maintain for certain period of time. (1 trip detection logic) |
|
WIRING DIAGRAM
Refer to the wiring diagram for DTC P0AA6-526 Click here.
Refer to the wiring diagram for DTC P321E-318 Click here.
INSPECTION PROCEDURE
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Drive the vehicle until the cumulative traveling time using the engine is a few minutes. (It is not required to keep driving using the engine.)
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A92-261 only is output, or DTCs except the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| Relevant DTC | |
|---|---|
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A51-174 | Drive Motor "A" Current Sensor Circuit |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-266, 267, 306, 586 | Drive Motor "A" Inverter Performance |
| P0A7A-203, 344 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0A94-585, 587, 589, 590 | DC / DC Converter Performance |
| P0AA6 (all INF codes)*1 | Hybrid Battery Voltage System Isolation Fault |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P3004-132 | High Voltage Power Resource |
Tech Tips
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0A92-261 may be stored due to a malfunction which causes the DTCs in the preceding table to be stored. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a reproduction test to check that no DTCs are output.
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
SIMULATION TEST
Turn the power switch on (READY).
Leave the vehicle for 1 minute with the engine on (with generator (MG1) rotating).
Tech Tips
If the accelerator pedal is depressed with the shift lever in P, the engine will start.
Connect the GTS to the DLC3.
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A92-261 is output or no DTCs are output. | A |
| P0A7A-344 or P0A92-521 is output. | B |
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check connection condition of the low voltage connector of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.
| *A | for LHD | *B | for RHD |
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
Tech Tips
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK POWER MANAGEMENT CONTROL ECU
Turn the power switch on (IG).
| *a | Component with harness connected (Power Management Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| NG |
|
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
for Type A:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
for Type B:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
| *1 | Generator Cable (Inverter with Converter Assembly Side) |
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected
| Specified Condition |
|---|
| T=8.0 N*m (82 kgf*cm, 71 in.*lbf) |
Note
Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Disconnect the generator cable from the inverter with converter assembly.
Check for arc marks at the terminals for the generator cable.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the generator cable to the inverter with converter assembly.
Install the inverter terminal cover.
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MG1)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
for Type A:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
for Type B:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
| *1 | Motor Cable |
| *2 | Generator Cable |
Disconnect the generator cable and motor cable from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
| *1 | Shield Ground |
| *a | Generator Cable (Inverter with Converter Assembly Side) |
Check generator (MG1) for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
Tech Tips
If the generator (MG1) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | ||||||||||||
|
||||||||||||
| for RHD | ||||||||||||
|
Tech Tips
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68° F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C)
When checking for a short circuit between motor phases without using a milliohmmeter.
Note
The motor generates current when wheels are rotated by hand. Before performing the inspection, wrap the motor cable terminals with insulation tape.
Tech Tips
A short circuit between the motor phases can be checked simply without using a milliohmmeter.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Note
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Move the shift lever to N.
Lift up the vehicle.
Rotate the rear wheels in the same direction simultaneously by hand.
| Standard |
|---|
| Left and right wheels rotate smoothly (No short circuit between phases) |
Tech Tips
If a short circuit exists between the motor phases, the rear wheels do not rotate smoothly (some resistance is felt).
Lower the vehicle.
Move the shift lever to P.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | ||||||||||||
|
||||||||||||
| for RHD | ||||||||||||
|
Measure the resistance according to the value(s) in the table below.
Tech Tips
Perform this procedure only when checking for a short circuit between motor phases without using a milliohmmeter.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||
|
|||||||||
| for RHD | |||||||||
|
Connect the generator cable and motor cable.
Install the inverter terminal cover.
| NG |
|
| OK |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY AND HYBRID VEHICLE TRANSMISSION ASSEMBLY
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A35 power management control ECU connector.
Disconnect the A38*1 or A74*2 inverter with converter assembly connector
*1: for LHD
*2: for RHD
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *a | Rear view of wire harness connector (to Power Management Control ECU) |
*b | Front view of wire harness connector (to Inverter with Converter Assembly) |
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
| for LHD | ||||||
|
||||||
| for RHD | ||||||
|
Note
Turning the power switch on (IG) with the power management control ECU and inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||||||||
|
|||||||||||||||
| for RHD | |||||||||||||||
|
Reconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Reconnect the A35 power management control ECU connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A38*1 or A74*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| *A | for LHD |
| *B | for RHD |
| *a | Component without harness connected (Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||
|
|||||||||
| for RHD | |||||||||
|
Reconnect the A38*1 or A74*2 inverter with converter assembly connector
*1: for LHD
*2: for RHD
| NG |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here |
| OK |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the hybrid vehicle transmission assembly Click here.
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m (82 kgf*cm, 71 in.*lbf) |
Note
Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Disconnect the generator cable from the hybrid vehicle transmission assembly.
Check for arc marks at the terminals for the generator cable.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the generator cable to the hybrid vehicle transmission assembly.
Install the hybrid vehicle transmission assembly.
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK GENERATOR CABLE
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the generator cable Click here.
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *1 | Shield ground | - | - |
| *a | Generator Cable (Inverter with Converter Assembly Side) |
*b | Generator Cable (Hybrid Vehicle Transmission Assembly Side) |
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | ||||||||||||
|
||||||||||||
| for RHD | ||||||||||||
|
Note
Wrap the terminal of the generator cable with insulating tape to prevent them from coming into contact with body ground.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| for LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| for RHD | |||||||||||||||||||||
|
Install the generator cable.
| NG |
|
REPLACE GENERATOR CABLE Click here |
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here