YAW RATE AND ACCELERATION SENSOR INSTALLATION

Tech Tips


  • Use the same procedure for the RHD and LHD vehicles.

  • The procedure listed below is for the LHD vehicles.


  1. INSTALL YAW RATE SENSOR


    1. Install the yaw rate sensor to the No. 1 console box mounting bracket with the 2 nuts.

      Torque:
      8.5 N*m  { 87 kgf*cm, 75 in.*lbf }

      Note

      Do not drop the yaw rate sensor. A yaw rate sensor that is dropped cannot be used.

  2. INSTALL NO. 1 CONSOLE BOX MOUNTING BRACKET


    1. Install the No. 1 console box mounting bracket with the 3 bolts.

      Torque:
      8.5 N*m  { 87 kgf*cm, 75 in.*lbf }

      Note


      • If the yaw rate sensor is dropped, replace it.

      • After installation, make sure that the sensor is not tilted due to the floor carpet or any foreign object being pinched by parts.

    2. Connect the sensor connector.

      Note

      Securely connect the connector.

    3. Attach the clamp and connect the indoor electrical key oscillator to the No. 1 console box mounting bracket.

  3. INSTALL CONSOLE BOX ASSEMBLY

    Click here

  4. PERFORM YAW RATE SENSOR ZERO POINT CALIBRATION

    Click here