HYBRID BATTERY SYSTEM, Diagnostic DTC:P0ABF-123, P0AC1-123, P0AC2-123

DTC Code DTC Name
P0ABF-123 Hybrid Battery Pack Current Sensor Circuit
P0AC1-123 Hybrid Battery Pack Current Sensor Circuit Low
P0AC2-123 Hybrid Battery Pack Current Sensor Circuit High

DESCRIPTION


DTC No. INF Code DTC Detection Condition Trouble Area

P0ABF

P0AC1

P0AC2

123 When the battery current sensor is abnormal (1 trip detection)
  • Hybrid battery junction block assembly

  • Battery smart unit

  • Harness or connector

WIRING DIAGRAM

A01FRJME02

INSPECTION PROCEDURE

CAUTION:


  • Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    At least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

PROCEDURE


  1. CHECK FOR DTCS (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Read output DTCs.

      Result
      Result Proceed to
      P0AFC-123 is not output. A
      P0AFC-123 is also output. B
    5. Turn the power switch off.


    B
    A
  2. CHECK HARNESS AND CONNECTOR (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY - BATTERY SMART UNIT)

    Note

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the upper hybrid battery cover sub-assembly Click here.

    3. Disconnect the battery current sensor connector from the hybrid battery junction block assembly.

    4. No. 4 hybrid vehicle battery carrier bracket sub-assembly Click here.

    5. A01FUA0E02

      Disconnect connector from the battery smart unit.

    6. A01FVVRE02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Battery Smart Unit)

      *b

      Front view of wire harness connector

      (to Hybrid Battery Junction Block Assembly)

      Measure the resistance according to the value(s) in the tables below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      z16-9 (IB) - z17-3 (IB) Power switch off Below 1 Ω
      z16-20 (GIB) - z17-2 (GIB) Power switch off Below 1 Ω
      z16-10 (VIB) - z17-1 (VIB) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      z16-9 (IB) or z17-3 (IB) - Body ground and other terminals Power switch off 10 kΩ or higher
      z16-20 (GIB) or z17-2 (GIB) - Body ground and other terminals Power switch off 10 kΩ or higher
      z16-10 (VIB) or z17-1 (VIB) - Body ground and other terminals Power switch off 10 kΩ or higher

      Note

      When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.

      Tech Tips

      Because the battery harness is not available as a supply part, if the harness cannot be repaired, replace the HV battery assembly.

    7. Connect the battery smart unit connector.

    8. Install the No. 4 hybrid vehicle battery carrier bracket sub-assembly.

    9. Connect the battery current sensor connector to the hybrid battery junction block assembly.

    10. Install the upper hybrid battery cover sub-assembly.


    NG
    OK
  3. CHECK BATTERY SMART UNIT (VIB VOLTAGE)

    Note

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 4 hybrid vehicle battery carrier bracket sub-assembly Click here.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. A01FQK9E03
      Text in Illustration
      *a

      Component with harness connected

      (Battery Smart Unit)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      z16-10 (VIB) - z16-20 (GIB) Power switch on (IG) 4.6 to 5.4 V

      Note

      Turning the power switch on (IG) with the service grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Install the No. 4 hybrid vehicle battery carrier bracket sub-assembly.


    NG
    OK
  4. CHECK BATTERY SMART UNIT (BATTERY CURRENT SENSOR OUTPUT VOLTAGE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 4 hybrid vehicle battery carrier bracket sub-assembly Click here.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. A01FQK9E04
      Text in Illustration
      *a

      Component with harness connected

      (Battery Smart Unit)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      z16-9 (IB) - z16-20 (GIB) Power switch on (IG) 2.46 to 2.54 V

      Note

      Turning the power switch on (IG) with the service grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Install the No. 4 hybrid vehicle battery carrier bracket sub-assembly.


    NG
    OK