HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A7A-344

DTC Code DTC Name
P0A7A-344 Generator Inverter Performance

DESCRIPTION

For a description of the inverter Click here.

If the MG1 torque execution value does not correspond to the torque command value from the MG ECU to MG1, the power management control ECU will store this DTC.

DTC No. INF Code DTC Detection Condition Trouble Area
P0A7A 344 MG1 torque execution monitoring malfunction
  • Hybrid vehicle transmission assembly

  • Generator cable

  • Inverter with converter assembly

  • Wire harness or connector

  • Power management control ECU

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AA6-526 Click here.

Refer to the wiring diagram for DTC P321E-318 Click here.

INSPECTION PROCEDURE

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      Only P0A7A-344 is output or P0A7A-344 and DTCs other than the ones in the table below are also output. A
      Any of the following DTCs are also output. B
      DTC No. Relevant Diagnosis
      P0A1A (all INF codes)*1 Generator Control Module
      P0A1B (all INF codes)*1 Drive Motor "A" Control Module
      P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
      P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance
      P0A41-245 Drive Motor "A" Position Sensor Circuit Low
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range/Performance
      P0A4D-255 Generator Position Sensor Circuit Low
      P0A60 (all INF codes)*1 Drive Motor "A" Phase V Current
      P0A63 (all INF codes)*1 Drive Motor "A" Phase W Current
      P0A72 (all INF codes)*1 Generator Phase V Current
      P0A75 (all INF codes)*1 Generator Phase W Current
      P0A78-266, 267, 279, 287, 503, 504, 505, 506, 586, 806, 807, 808 Drive Motor "A" Inverter Performance
      P0A7A-203, 325, 517, 518, 809, 810, 811 Generator Inverter Performance
      P0A94-547, 548, 549, 554, 555, 556, 585, 587, 589, 590 DC/DC Converter Performance
      P0AA6 (all INF codes)*1 Hybrid Battery Voltage System Isolation Fault
      P0C76-523 Hybrid Battery System Discharge Time Too Long
      P3004-132 High Voltage Power Resource

      Tech Tips


      • *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

      • P0A7A-344 may be output due to a malfunction which also causes DTCs in the preceding table to be output. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

    5. Turn the power switch off.


    B
    A
  2. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      Any of the following DTCs are also output. A
      Only P0A7A-344 is output or P0A7A-344 and DTCs other than the ones in the table below are also output. B
      DTC No. Relevant Diagnosis
      P0A78-306 Drive Motor "A" Inverter Performance
      P0A90-251, 509 Drive Motor "A" Performance

      Tech Tips

      When the DTCs listed in the table above are also output, there may be a short between the HSDN (MG shut down signal) circuit and power circuit.

    5. Turn the power switch off.


    B
    A
  3. CHECK POWER MANAGEMENT CONTROL ECU


    1. Turn the power switch on (IG).

    2. A01FVOIE23
      Text in Illustration
      *a

      Component with harness connected

      (Power Management Control ECU)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A35-30 (HSDN) - N91-6 (E1) Power switch on (IG) Below 4.5 V
    3. Turn the power switch off.


    NG
    OK
  4. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly Click here.

      Note

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector cannot be pulled out.

      A01FRBVE01
      Text in Illustration
      *A for LHD *B for RHD
      OK
      The connectors are connected securely and there are no contact pressure problems.

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.


    NG
    OK
  5. CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01FRI1E01
      Text in Illustration
      *A for LHD
      *B for RHD

      for Type A:


      1. Remove the inverter terminal cover from the inverter with converter assembly.

    3. A01FV5DE02
      Text in Illustration
      *A for LHD
      *B for RHD

      for Type B:


      1. Remove the inverter terminal cover from the inverter with converter assembly.

    4. A01FTL0E01
      Text in Illustration
      *A for LHD
      *B for RHD
      *1 Generator Cable

      Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

      Specified Condition
      T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

      Note

      Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

    5. Disconnect the generator cable from the inverter with converter assembly.

    6. Check for arc marks at the terminals for the generator cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    7. Connect the generator cable to the inverter with converter assembly.

    8. Install the inverter terminal cover.


    B
    C
    A
  6. CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MG1)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01FRI1E01
      Text in Illustration
      *A for LHD
      *B for RHD

      for Type A:


      1. Remove the inverter terminal cover from the inverter with converter assembly.

    3. A01FV5DE02
      Text in Illustration
      *A for LHD
      *B for RHD

      for Type B:


      1. Remove the inverter terminal cover from the inverter with converter assembly.

    4. A01FRCRE01
      Text in Illustration
      *A for LHD
      *B for RHD
      *1 Generator Cable
      *2 Motor Cable

      Disconnect the generator cable and motor cable from the inverter with converter assembly.

    5. A01FSH3E01
      Text in Illustration
      *A for LHD
      *B for RHD
      *1 Shield Ground
      *a

      Generator Cable

      (Inverter with Converter Assembly Side)

      Check MG1 for an interphase short using a milliohmmeter.


      1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

        Tech Tips

        If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

        Standard Resistance
        for LHD
        Tester Connection Switch Condition Specified Condition
        v1-3 (W) - v1-1 (U) Power switch off 31.9 to 35.0 mΩ
        v1-2 (V) - v1-3 (W) Power switch off 31.8 to 34.9 mΩ
        v1-1 (U) - v1-2 (V) Power switch off 33.0 to 36.1 mΩ
        for RHD
        Tester Connection Switch Condition Specified Condition
        v1-1 (W) - v1-3 (U) Power switch off 31.4 to 34.6 mΩ
        v1-2 (V) - v1-1 (W) Power switch off 31.3 to 34.5 mΩ
        v1-3 (U) - v1-2 (V) Power switch off 32.5 to 35.7 mΩ

        Tech Tips

        To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).


        • R20 = Rt / {1 + 0.00393 X (T - 20)}

        The calculation is based on the following:


        • R20: Resistance at 20°C (68° F) (mΩ)

        • Rt: Measured resistance (mΩ)

        • T: Temperature when the resistance is measured (°C)

    6. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      v1-3 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      v1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      v1-1 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      v1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      v1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      v1-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
    7. Connect the generator cable and motor cable.

    8. Install the inverter terminal cover.


    NG
    OK
  7. CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the hybrid vehicle transmission assembly Click here.

    3. A01FTSA

      Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

      Specified Condition
      T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

      Note

      Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

    4. Disconnect the generator cable from the hybrid vehicle transmission assembly.

    5. Check for arc marks at the terminals for the generator cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    6. Connect the generator cable to the hybrid vehicle transmission assembly.

    7. Install the hybrid vehicle transmission assembly.


    B
    C
    A
  8. CHECK GENERATOR CABLE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the generator cable Click here.

    3. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      A01FVLBE01
      Text in Illustration
      *A for LHD *B for RHD
      *1 Shield ground - -
      *a

      Generator Cable

      (Inverter with Converter Assembly Side)

      *b

      Generator Cable

      (Hybrid Vehicle Transmission Assembly Side)

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      v1-3 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      v1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      v1-1 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      v1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      v1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      v1-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher

      Note

      Wrap the terminals of the generator cable with insulating tape to prevent them from coming into contact with the body ground.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      v1-3 (W) - v2-1 (W) Power switch off Below 1 Ω
      v1-2 (V) - v2-2 (V) Power switch off Below 1 Ω
      v1-1 (U) - v2-3 (U) Power switch off Below 1 Ω
      v1-3 (W) - v2-3 (U) Power switch off 100 MΩ or higher
      v1-2 (V) - v2-1 (W) Power switch off 100 MΩ or higher
      v1-1 (U) - v2-2 (V) Power switch off 100 MΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      v1-1 (W) - v2-1 (W) Power switch off Below 1 Ω
      v1-2 (V) - v2-2 (V) Power switch off Below 1 Ω
      v1-3 (U) - v2-3 (U) Power switch off Below 1 Ω
      v1-1 (W) - v2-3 (U) Power switch off 100 MΩ or higher
      v1-2 (V) - v2-1 (W) Power switch off 100 MΩ or higher
      v1-3 (U) - v2-2 (V) Power switch off 100 MΩ or higher
    5. Install the generator cable.


    NG
    OK
  9. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the connector from the inverter with converter assembly.

    3. Disconnect the connector from the power management control ECU.

    4. Connect the cable to the negative (-) auxiliary battery terminal.

    5. Turn the power switch on (IG).

    6. A01FV1HE05
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *b

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-25 (HSDN) or A35-30 (HSDN) - Body ground Power switch on (IG) Below 1 V
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-25 (HSDN) or A35-30 (HSDN) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    7. Turn the power switch off.

    8. Disconnect the cable from the negative (-) auxiliary battery terminal.

    9. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-25 (HSDN) - A38-10 (+B) Power switch off 10 kΩ or higher
      A38-25 (HSDN) - A38-11 (+B2) Power switch off 10 kΩ or higher
      A35-30 (HSDN) - A35-1 (+B2) Power switch off 10 kΩ or higher
      A35-30 (HSDN) - A35-4 (MREL) Power switch off 10 kΩ or higher
      A35-30 (HSDN) - A35-5 (FCTL) Power switch off 10 kΩ or higher
      A35-30 (HSDN) - A35-19 (GI) Power switch off 10 kΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-25 (HSDN) - A74-10 (+B) Power switch off 10 kΩ or higher
      A74-25 (HSDN) - A74-11 (+B2) Power switch off 10 kΩ or higher
      A35-30 (HSDN) - A35-1 (+B2) Power switch off 10 kΩ or higher
      A35-30 (HSDN) - A35-4 (MREL) Power switch off 10 kΩ or higher
      A35-30 (HSDN) - A35-5 (FCTL) Power switch off 10 kΩ or higher
      A35-30 (HSDN) - A35-19 (GI) Power switch off 10 kΩ or higher
    10. Connect the inverter with converter assembly connector.

    11. Connect the power management control ECU connector.


    NG
    OK
  10. CHECK INVERTER WITH CONVERTER ASSEMBLY

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the connector from the inverter with converter assembly.

    3. A01FRVVE07
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Component without harness connected

      (Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-25 (HSDN) - A38-10 (+B) Power switch off 5 kΩ or higher
      A38-25 (HSDN) - A38-11 (+B2) Power switch off 5 kΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-25 (HSDN) - A74-10 (+B) Power switch off 5 kΩ or higher
      A74-25 (HSDN) - A74-11 (+B2) Power switch off 5 kΩ or higher
    4. Connect the inverter with converter assembly connector.


    NG
    OK