Tech Tips
Perform "Inspection After Repairs" after replacing the heated oxygen sensor Click here.
INSTALL HEATED OXYGEN SENSOR
| *1 | Fulcrum Length |
for Bank 2 Sensor 2:
Using SST, install the heated oxygen sensor.
Tech Tips
Use a torque wrench with a fulcrum length of 300 mm (11.8 in.). When using a torque wrench with a fulcrum length that is not 300 mm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification Click here.
Make sure SST and the wrench are connected in a straight line.
Perform "Inspection After Repairs" after replacing the heated oxygen sensor Click here.
| *1 | Fulcrum Length |
for Bank 1 Sensor 2:
Using SST, install the heated oxygen sensor.
Tech Tips
Use a torque wrench with a fulcrum length of 300 mm (11.8 in.). When using a torque wrench with a fulcrum length that is not 300 mm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification Click here.
Make sure SST and the wrench are connected in a straight line.
Perform "Inspection After Repairs" after replacing the heated oxygen sensor Click here.
Pass the heated oxygen sensor connector through the floor panel and install the grommet.
CONNECT HEATED OXYGEN SENSOR CONNECTOR
for Bank 1 Sensor 2:
Connect the heated oxygen sensor connector.
for Bank 2 Sensor 2:
Connect the heated oxygen sensor connector.
INSTALL INSTRUMENT PANEL FINISH PANEL END RH
INSPECT FOR EXHAUST GAS LEAK
Tech Tips
If an exhaust gas leak has been repaired, perform an inspection following the repair Click here.
If gas is leaking, tighten the areas necessary to stop the leak. Replace damaged parts as necessary.