DESCRIPTION
Refer to the description for DTC P0AE6-225 Click here.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P3004 | 800 | Excessive overcurrent occurs during precharge (time from when SMRP turns on until when SMRG turns on). |
|
| P3004 | 801 | Minimal overcurrent occurs during precharge (time from when SMRP turns on until when SMRG turns on). |
INSPECTION PROCEDURE
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Tech Tips
After the repair, clear the DTCs, perform the following procedure and check that the same DTC (including pending DTC) is not output.
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (READY) and wait for 30 seconds or more.
PROCEDURE
CHECK DTC OUTPUT (HV)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A09-265 | DC/DC Converter Status Circuit Low Input |
| P0A10-263 | DC/DC Converter Status Circuit High Input |
Tech Tips
P3004-800 or P3004-801 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.
Turn the power switch off.
| B |
|
GO TO DTC CHART Click here |
| A |
|
CHECK DTC OUTPUT (HV)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| DTC No. | Relevant Diagnosis |
|---|---|
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit |
| P0AC0-123 | Hybrid Battery Pack Current Sensor Circuit Range / Performance |
| P0AC1-123 | Hybrid Battery Pack Current Sensor Circuit Low |
| P0AC2-123 | Hybrid Battery Pack Current Sensor Circuit High |
| P0AFC-123 | Hybrid Battery Pack Sensor Module |
| P0B3D-123 | Hybrid Battery Voltage Sensor "A" Circuit Low |
| P0B42-123 | Hybrid Battery Voltage Sensor "B" Circuit Low |
| P0B47-123 | Hybrid Battery Voltage Sensor "C" Circuit Low |
| P0B4C-123 | Hybrid Battery Voltage Sensor "D" Circuit Low |
| P0B51-123 | Hybrid Battery Voltage Sensor "E" Circuit Low |
| P0B56-123 | Hybrid Battery Voltage Sensor "F" Circuit Low |
| P0B5B-123 | Hybrid Battery Voltage Sensor "G" Circuit Low |
| P0B60-123 | Hybrid Battery Voltage Sensor "H" Circuit Low |
| P0B65-123 | Hybrid Battery Voltage Sensor "I" Circuit Low |
| P0B6A-123 | Hybrid Battery Voltage Sensor "J" Circuit Low |
| P0B6F-123 | Hybrid Battery Voltage Sensor "K" Circuit Low |
| P0B74-123 | Hybrid Battery Voltage Sensor "L" Circuit Low |
| P0B79-123 | Hybrid Battery Voltage Sensor "M" Circuit Low |
| P0B7E-123 | Hybrid Battery Voltage Sensor "N" Circuit Low |
| P0B83-123 | Hybrid Battery Voltage Sensor "O" Circuit Low |
| P308A-123 | Hybrid Battery Voltage Detection Circuit Open |
| U029A-123 | Lost Communication with Hybrid Battery Pack Sensor Module |
Tech Tips
P3004-800 or P3004-801 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.
Turn the power switch off.
| B |
|
GO TO DTC CHART Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)
Check the connections of the power management control ECU connectors.
| *1 | for LHD | *2 | for RHD |
| OK |
|---|
| The connectors are connected securely and there are no contact problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK COMPRESSOR WITH MOTOR ASSEMBLY
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Disconnect the No. 2 engine wire (air conditioning harness) E3 from the inverter with converter assembly.
| *1 | No. 2 Engine Wire (Air Conditioning Harness) |
| *2 | Shielded Wire Ground |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Note
Do not use a megohmmeter.
Read the resistance after the value has stabilized.
Tech Tips
The polarities of the tester probes may differ depending on the tester. Use the current output probe of the tester as the positive probe for this measurement. To determine the polarity, use another voltmeter to confirm the current output probe of the tester. When measuring the output of the tester, the voltmeter positive probe indicates the tester current output probe.
Connect the No. 2 engine wire (air conditioning harness) from the inverter with converter assembly.
Install the inverter terminal cover to the inverter with converter assembly.
| NG |
|
CHECK NO. 2 ENGINE WIRE Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER)
Disconnect connector A59 from the inverter with converter assembly.
Disconnect connector A21 from power management control ECU.
| *1 | Rear view of wire harness connector (to Power Management Control ECU) |
| *2 | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for open) | ||||||
|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for short) | ||||||
|---|---|---|---|---|---|---|
|
Connect the power management control ECU connector.
Connect the inverter with converter assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK POWER MANAGEMENT CONTROL ECU
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Component with harness connected (Power Management Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
| NG |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here |
| OK |
|
CHECK FRAME WIRE
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Disconnect the frame wire (high voltage DC connector) T1 from the inverter with converter assembly.
Remove the upper hybrid battery cover sub-assembly Click here.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Install the upper hybrid battery cover sub-assembly Click here.
Connect the frame wire (high voltage DC connector) to inverter with converter assembly.
Install the inverter terminal cover to the inverter with converter assembly.
| NG |
|
CHECK HYBRID BATTERY JUNCTION BLOCK Click here |
| OK |
|
REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS Click here
CHECK NO. 2 ENGINE WIRE
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Disconnect the No. 2 engine wire (air conditioning harness) E3 from the inverter with converter assembly.
| *1 | Green Lock |
Disconnect the No. 2 engine wire (air conditioning harness) E1 from the compressor with motor assembly.
| *1 | No. 2 Engine Wire (Air Conditioning Harness) |
| *2 | Shielded Wire Ground |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the No. 2 engine wire (air conditioning harness) to the compressor with motor assembly.
Connect the No. 2 engine wire (air conditioning harness) from the inverter with converter assembly.
Install the inverter terminal cover to the inverter with converter assembly.
| NG |
|
REPLACE NO. 2 ENGINE WIRE |
| OK |
|
REPLACE COMPRESSOR WITH MOTOR ASSEMBLY Click here
CHECK HYBRID BATTERY JUNCTION BLOCK
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper hybrid battery cover sub-assembly Click here.
Disconnect the frame wire T3 and T4 from the hybrid battery junction block.
| *1 | Hybrid Battery Junction Block |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the frame wire to the hybrid battery junction block.
Install the upper hybrid battery cover sub-assembly Click here.
| NG |
|
REPLACE HYBRID BATTERY JUNCTION BLOCK Click here |
| OK |
|
REPLACE FRAME WIRE Click here