PRECAUTION (w/ Air Suspension)
Note
Be sure to read Precaution thoroughly before servicing Click here.
REMOVE FRONT FLOOR COVER LH
| *1 | Bolt |
| *2 | Screw |
Remove the clip (A).
Disconnect the 2 clips (B).
Remove the 2 screws, 4 bolts and front floor cover LH.
REMOVE OXYGEN SENSOR
Disconnect the 2 wire harness clamps and oxygen sensor connector.
Disconnect the wire harness clamp.
Using SST, remove the oxygen sensor from the No. 3 front exhaust pipe sub-assembly.
REMOVE NO. 3 FRONT EXHAUST PIPE SUB-ASSEMBLY
Remove the 2 bolts and 2 compression springs.
Remove the 2 bolts, 2 nuts and No. 3 front exhaust pipe sub-assembly.
Remove the 3 gaskets from the No. 3 front exhaust pipe sub-assembly.
REMOVE FRONT EXHAUST PIPE ASSEMBLY
Disconnect the clamp and No. 2 oxygen sensor connector (for Bank 2 Sensor 2).
Loosen the bolt (A).
Remove the 2 bolts (B), 2 nuts and front exhaust pipe assembly.
Remove the gasket from the front exhaust pipe assembly.
REMOVE NO. 2 OXYGEN SENSOR
Using SST, remove the No. 2 oxygen sensor from the front exhaust pipe assembly.