ECM INSTALLATION


  1. INSTALL ECM


    1. A006TC9

      Install the 2 brackets to the ECM with the 4 screws.

    2. A006TF2

      Install the ECM with bracket with the 2 bolts.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    3. A006SSA

      Connect the 2 ECM connectors and lower the 2 levers.

      Note


      • When connecting the connector, make sure that dirt, water or other foreign matter is not stuck between the connector and ECM.

      • Make sure that the 2 levers are securely lowered.

  2. INSTALL NO. 2 AIR CLEANER INLET


    1. A006WQD

      Install the No. 2 air cleaner inlet with the bolt.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
  3. INSTALL NO. 1 AIR CLEANER INLET


    1. A006WJC

      Install the No. 1 air cleaner inlet with the clip.

  4. INSTALL AIR CLEANER CASE SUB-ASSEMBLY


    1. A00OUZE

      Install the air cleaner case with the 3 bolts.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
  5. INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

  6. INSTALL AIR CLEANER CAP SUB-ASSEMBLY


    1. Connect the air cleaner hose.

    2. A00OVRGE01

      Attach the 4 clamps to install the air cleaner cap.

    3. Connect the No. 2 ventilation hose.

    4. Attach the clamp and connect the mass air flow meter connector.

  7. INSTALL RADIATOR SUPPORT OPENING COVER


    1. A00E83X

      Install the radiator support opening cover with the 8 clips.

  8. INSTALL NO. 1 ENGINE COVER


    1. A003DQW

      Attach the 4 clips to install the No. 1 engine cover.

  9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  10. INSTALL ENGINE ROOM SIDE COVER


    1. A003B3G

      Remove the clip and engine room side cover.

  11. PERFORM REGISTRATION


    1. Perform learning values write Click here.

  12. PERFORM INITIALIZATION


    1. Perform the supply pump initialization procedure Click here.

  13. PERFORM THROTTLE VALVE FULLY CLOSED POSITION LEARNING

    Tech Tips

    Be sure to turn off the ignition switch before performing this inspection.


    1. Turn the ignition switch to ON.

    2. Turn the ignition switch off and wait 10 seconds.

      Tech Tips

      The fully closed position of the diesel throttle valve is learned when the ignition switch is turned off.