INSTALL ECM
Install the 2 brackets to the ECM with the 4 screws.
Install the ECM with bracket with the 2 bolts.
Connect the 2 ECM connectors and lower the 2 levers.
Note
When connecting the connector, make sure that dirt, water or other foreign matter is not stuck between the connector and ECM.
Make sure that the 2 levers are securely lowered.
INSTALL NO. 2 AIR CLEANER INLET
Install the No. 2 air cleaner inlet with the bolt.
INSTALL NO. 1 AIR CLEANER INLET
Install the No. 1 air cleaner inlet with the clip.
INSTALL AIR CLEANER CASE SUB-ASSEMBLY
Install the air cleaner case with the 3 bolts.
INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
INSTALL AIR CLEANER CAP SUB-ASSEMBLY
Connect the air cleaner hose.
Attach the 4 clamps to install the air cleaner cap.
Connect the No. 2 ventilation hose.
Attach the clamp and connect the mass air flow meter connector.
INSTALL RADIATOR SUPPORT OPENING COVER
Install the radiator support opening cover with the 8 clips.
INSTALL NO. 1 ENGINE COVER
Attach the 4 clips to install the No. 1 engine cover.
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
INSTALL ENGINE ROOM SIDE COVER
Remove the clip and engine room side cover.
PERFORM REGISTRATION
Perform learning values write Click here.
PERFORM INITIALIZATION
Perform the supply pump initialization procedure Click here.
PERFORM THROTTLE VALVE FULLY CLOSED POSITION LEARNING
Tech Tips
Be sure to turn off the ignition switch before performing this inspection.
Turn the ignition switch to ON.
Turn the ignition switch off and wait 10 seconds.
Tech Tips
The fully closed position of the diesel throttle valve is learned when the ignition switch is turned off.