FRONT PASSENGER AIRBAG ASSEMBLY INSTALLATION


  1. INSTALL INSTRUMENT PANEL WIRE ASSEMBLY


    1. A01CFSP

      Connect the 2 airbag connectors to install the instrument panel wire assembly to the front passenger airbag assembly.

      Note

      When connecting any airbag connector, take care not to damage the airbag wire harness.

  2. INSTALL FRONT PASSENGER AIRBAG ASSEMBLY


    1. A01CEKZ

      Engage the 5 hooks.

    2. Turn the front passenger airbag assembly in the direction indicated by the arrow shown in the illustration.

    3. A01CAVW

      Engage the 5 hooks and install the front passenger airbag assembly on the instrument panel.

    4. A01CBZE

      Install the 2 screws.

    5. A01CFCU

      Engage the wire harness clamp.

  3. INSTALL UPPER INSTRUMENT PANEL SUB-ASSEMBLY

    Tech Tips

    It is possible to install the instrument panel register assembly with the upper instrument panel sub-assembly still installed to the vehicle body. Refer to the reassembly procedure for the upper instrument panel sub-assembly.


    1. Engage the 5 claws.

      A01CEGJ

      Note


      • Do not allow the wire harness to get caught in the claws.

      • Make sure that the claws are fully engaged.

    2. Engage the 9 claws.

    3. Install the 2 clips.

    4. Connect the connector.

      A01CBP0
    5. Install the 2 passenger airbag bolts <A>.

      Torque:
      20 N*m  { 204 kgf*cm, 15 ft.*lbf }
    6. Install the upper instrument panel sub-assembly with the 3 screws <B>.

      A01CC6KE01
  4. CONNECT INSTRUMENT PANEL WIRE ASSEMBLY


    1. Check that the engine switch is off.

    2. Check that the cable is disconnected from the negative (-) battery terminal.

      CAUTION:

      Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.

    3. A01CFH6

      Connect the connector.

      Note

      When connecting the airbag connector, take care not to damage the airbag wire harness.

    4. Engage the wire harness clamp.

  5. INSTALL NO. 3 INSTRUMENT CLUSTER FINISH PANEL GARNISH

    Tech Tips

    Refer to the procedure from "Install No. 3 Instrument Cluster Finish Panel Garnish" Click here.

  6. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  7. PERFORM DIAGNOSTIC SYSTEM CHECK


    1. Perform a diagnostic system check Click here.

  8. INSPECT SRS WARNING LIGHT


    1. Inspect the SRS warning light Click here.