AUTOMATIC TRANSMISSION SYSTEM (for 1VD-FTV), Diagnostic DTC:P2716

DTC Code DTC Name
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

DESCRIPTION

Refer to DTC P0894 Click here.

DTC Code DTC Detection Condition Trouble Area
P2716

Conditions (a) or (b) below are detected for 1 sec. or more (1 trip detection logic).

(a) SLT - terminal: 0 V

(b) SLT - terminal: 12 V


  • Open or short in shift solenoid valve SLT circuit

  • Shift solenoid valve SLT

  • ECM

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

WIRING DIAGRAM

A0155BSE08

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)


    1. A0157O4E14

      Disconnect the No. 1 transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      13 (SLT+) - 5 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      13 (SLT+) - Body ground Always 10 kΩ or higher
      5 (SLT-) - Body ground Always 10 kΩ or higher

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)

    A015B7PE25

    1. Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      C45-11 (SLT+) - C45-10 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      C45-11 (SLT+) - Body ground Always 10 kΩ or higher
      C45-10 (SLT-) - Body ground Always 10 kΩ or higher
      for RHD
      Tester Connection Condition Specified Condition
      C46-11 (SLT+) - C46-10 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      C46-11 (SLT+) - Body ground Always 10 kΩ or higher
      C46-10 (SLT-) - Body ground Always 10 kΩ or higher

    NG
    OK
  3. INSPECT SHIFT SOLENOID VALVE SLT


    1. A01599DE01

      Remove the shift solenoid valve SLT.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 2

      • Battery negative (-) → Terminal 1

      Valve moves and makes an operating noise

    NG
    OK