CAUTION / NOTICE / HINT
Note
When removing the cooler expansion valve by itself, be sure to install a new cooler expansion valve and new bolt for the suction pipe sub-assembly.
PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
REMOVE WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY
REMOVE FRONT OUTER COWL TOP PANEL SUB-ASSEMBLY
DISCONNECT NO. 1 BRAKE ACTUATOR TUBE
DISCONNECT SUCTION PIPE SUB-ASSEMBLY
DISCONNECT AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY
REMOVE COOLER EXPANSION VALVE
Using a 4 mm hexagon wrench, remove the 2 hexagon bolts.
| *a | Bolt for Suction Pipe Sub-assembly |
Temporarily install the bolt for the suction pipe sub-assembly halfway to the cooler expansion valve.
Hold the bolt and pull it to remove the cooler expansion valve as shown in the illustration.
| *1 | No. 1 Cooler Evaporator Sub-assembly |
Remove the 2 O-rings from the No. 1 cooler evaporator sub-assembly.