PROCEDURE
INSTALL WATER TEMPERATURE SENSOR
To prevent contamination by foreign matter, remove the protective tape from the water temperature sensor connecting portions of the FC cooling water pump inlet pipe immediately before performing the procedure.
| *a | Fulcrum Length of 19 mm Union Nut Wrench |
| *b | Fulcrum Length of Torque Wrench |
Using a 19 mm union nut wrench, install the water temperature sensor and a new gasket to the FC cooling water pump inlet pipe.
Note
If the water temperature sensor is dropped or subjected to a strong impact, replace it with a new one.
Tech Tips
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
When using a union nut wrench (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 162 mm (6.38 in.)): 16.5 N*m (168 kgf*cm, 12 ft.*lbf)
Connect the water temperature sensor connector.
INSTALL REAR MOTOR UNDER COVER RH
ADD COOLANT (FC STACK COOLANT)
INSPECT FOR COOLANT (FC STACK COOLANT)
INSTALL SUSPENSION MEMBER TO FRONT CROSSMEMBER BRACE SUB-ASSEMBLY
INSTALL FRONT FLOOR COVER RH
INSTALL FRONT FLOOR COVER LH
INSTALL NO. 2 MOTOR UNDER COVER
INSTALL FRONT BUMPER LOWER ABSORBER