INTAKE AIR FLOW METER INSTALLATION

PROCEDURE


  1. INSTALL MASS AIR FLOW METER

    Tech Tips

    Perform "Inspection After Repair" after replacing the mass air flow meter.

    Click here


    1. Install the mass air flow meter to the air cleaner cap sub-assembly with the 2 screws.

      Torque:
      1.0 N*m  { 10 kgf*cm, 9 in.*lbf }

      Note


      • If the mass air flow meter is dropped or subjected to a strong impact, replace it with a new one.

      • If reusing the mass air flow meter, be sure to inspect the O-ring.

      • Make sure that the O-ring is not damaged or does not jump out of position during installation.

    2. Connect the mass air flow meter connector.