| DTC Code | DTC Name |
|---|---|
| P1D10-450 | U Phase IPM Circuit |
| P1D13-450 | V Phase IPM Circuit |
| P1D16-450 | W Phase IPM Circuit |
| P1D19-450 | X Phase IPM Circuit |
DESCRIPTION
For the description of the FC converter assembly, refer to the wiring diagram for DTC P1D1E-450.
If a malfunction occurs in the FC converter assembly internal circuits, the FC boost control ECU detects a malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate |
|---|---|---|---|---|
| P1D10-450 | U Phase IPM Circuit | U phase fail signal is detected. (Malfunction in circuit) (1 trip detection logic) |
|
Master Warning Light: Comes on |
| P1D13-450 | V Phase IPM Circuit | V phase fail signal is detected. (Malfunction in circuit) (1 trip detection logic) |
|
Master Warning Light: Comes on |
| P1D16-450 | W Phase IPM Circuit | W phase fail signal is detected. (Malfunction in circuit) (1 trip detection logic) |
|
Master Warning Light: Comes on |
| P1D19-450 | X Phase IPM Circuit | X phase fail signal is detected. (Malfunction in circuit) (1 trip detection logic) |
|
Master Warning Light: Comes on |
Tech Tips
These DTCs will be stored due to a malfunction in the detection circuit inside the FC converter assembly.
| DTC No. | Data List |
|---|---|
| P1D10-450 |
|
| P1D13-450 |
|
| P1D16-450 |
|
| P1D19-450 |
|
CAUTION / NOTICE / HINT
CAUTION:
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grips from both FC stack assembly and EV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV battery
Disconnecting the low voltage connector of the FC stack assembly
Disconnecting the low voltage connector of the FC converter assembly
Tech Tips
No removal order is specified for the service plug grips of the FC stack assembly and EV battery.
After removing the service plug grip from the EV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system. After removing the service grip from the FC stack assembly, store it in a safe location and use the "HIGH-VOLTAGE, DO NOT TOUCH" sign to notify other technicians that you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removal of the service plug grips of both FC stack assembly and EV battery, wait for at least 10 minutes before touching the high-voltage connectors and terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
At least 10 minutes are necessary to discharge the high-voltage capacitors inside the inverter with converter assembly and FC stack assembly.
Note
When reinstalling the service plug grip to the FC stack assembly or the EV battery, slide the lever of the service plug until the letters "UNLOCK" are completely hidden, and insert it firmly.
When the vehicle is parked with the power switch off, if the FC control ECU judges that the FC stack temperature will go below 0°C (32°F), it activates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds and drains water from the FC stack assembly. When performing inspection or repairs with the power switch off (not on (IG) or on (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work (If the auxiliary battery voltage is needed to conduct inspection, warm up the FC system beforehand).
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
After the inspection is complete, be sure to replace the FC converter assembly (The FC converter may have been damaged due to circuit malfunction).
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (IG).
Enter the following menus: Powertrain / FC / Data List / FC Mode, FC Intermittent Operation.
Move the shift lever to P, turn the power switch on (READY) and wait until the FC system is activated (Waiting for at least 2 minutes is required after turning the power switch on).
FC system is activated: Data List shows that "FC Mode" is "FC Working" and "FC Intermittent Operation" is "OFF".
Wait at least 15 seconds with the FC system activated.
PROCEDURE
CHECK DTC OUTPUT (FCDC)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / FCDC / Trouble Codes.
Check for DTCs.
| Result | ||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||
Tech Tips
DTC P1D10-450, P1D13-450, P1D16-450 or P1D19-450 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the power switch off.
| B |
|
GO TO DTC CHART (FC BOOST CONTROL SYSTEM) Click here |
| A |
|
CHECK DTC OUTPUT (EV)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / EV / Trouble Codes.
Check for DTCs.
| Result | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||
|
||||||||||||||||||
Tech Tips
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
DTC P1D10-450, P1D13-450, P1D16-450 or P1D19-450 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (FC CONVERTER ASSEMBLY CONNECTOR)
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed to FC stack assembly and EV battery.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connection condition of the FC converter assembly connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed to FC stack assembly and EV battery.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connection condition of the low voltage connector of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK COOLING SYSTEM
Tech Tips
If the "Cooling System" inspection results are normal, perform the next step.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHECK FC AIR COMPRESSOR RESOLVER CIRCUIT
Tech Tips
If the "FC Air Compressor Resolver Circuit" inspection results are normal, perform the next step.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHECK MOTOR RESOLVER CIRCUIT
Tech Tips
If the "Motor Resolver Circuit" inspection results are normal, perform the next step.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHECK FC AIR COMPRESSOR HIGH-VOLTAGE CIRCUIT
Tech Tips
If the "FC Air Compressor High-voltage Circuit" inspection results are normal, perform the next step.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHECK MOTOR HIGH-VOLTAGE CIRCUIT
Tech Tips
If the "Motor High-voltage Circuit" inspection results are normal, perform the next step.
| Result | ||
|---|---|---|
|
| NEXT |
|
REPLACE FC CONVERTER ASSEMBLY
| Result | ||
|---|---|---|
|
| NEXT |
|
CLEAR DTC
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / FCDC / Trouble Codes.
Clear the DTCs.
| Result | ||
|---|---|---|
|
Turn the power switch off and wait for 3 minutes or more.
| NEXT |
|
CHECK DTC OUTPUT (FCDC)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / FC / Data List / FC Mode, FC Intermittent Operation.
| Tester Display |
|---|
| FC Mode |
| FC Intermittent Operation |
Move the shift lever to P, turn the power switch on (READY) and wait until the FC system is activated. (Waiting for at least 2 minutes is required after turning the power switch on)
Tech Tips
FC system is activated: Data List shows that "FC Mode" is "FC Working" and "FC Intermittent Operation" is "OFF".
Wait at least 15 seconds with the FC system activated.
Drive the vehicle forward with the shift lever in D for 5 m (16 ft.) or more.
Drive the vehicle backward with the shift lever in R for 5 m (16 ft.) or more.
Enter the following menus: Powertrain / FCDC / Trouble Codes.
Check for DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| A |
|
END |
| B |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here |