| DTC Code | DTC Name |
|---|---|
| P0A94-172 | Boosting Converter Performance |
DTC SUMMARY
MALFUNCTION DESCRIPTION
This DTC indicates that a large current flowed in the boost converter. The cause of this malfunction may be one of the following:
| Area | Main Malfunction Description | Step |
|---|---|---|
| Inverter low-voltage circuit | The connectors are not connected properly | 3 |
| Resolver | Open or short circuit in the drive motor resolver or FC air compressor motor resolver circuit | 4, 5 |
| Drive motor, FC air compressor motor |
|
6, 7 |
| FC converter assembly low-voltage circuit | The connectors are not connected properly | 9 |
| FC converter assembly high-voltage line circuit | High-voltage line circuit malfunction (From FC converter assembly to inverter with converter assembly) | 10, 11, 12, 13, 14 |
DESCRIPTION
For a description of the boost converter.
Refer to high voltage system diagram for the System Description.
If a malfunction occurs in the boost converter, the MG ECU detects it and transmits this information to the hybrid vehicle control ECU.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate |
|---|---|---|---|---|
| P0A94-172 | Boosting Converter Performance | Boost converter fail signal detected (overcurrent due to system malfunction): A malfunction is detected in any of the boost converter components (inverter, hybrid vehicle transaxle assembly, MG ECU, etc.). (1 trip detection logic) |
|
Master Warning Light: Comes on |
*: This DTC is output when a large current flows in the boost converter and there is no history information indicating the specific part.
Check related parts (inverter, FC converter assembly, drive motor, FC air compressor motor, resolver, cable, wire harness, EV control ECU).
WIRING DIAGRAM
Refer to the wiring diagram for DTC P1D8F-479.
Refer to the wiring diagram for DTC P0AA6-485.
Refer to the wiring diagram for DTC P324E-788.
Refer to the wiring diagram for the inverter low-voltage circuit.
CAUTION / NOTICE / HINT
CAUTION:
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grips from both FC stack assembly and EV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV battery
Disconnecting the low voltage connector of the FC stack assembly
Disconnecting the low voltage connector of the FC converter assembly
Tech Tips
No removal order is specified for the service plug grips of the FC stack assembly and EV battery.
After removing the service plug grip from the EV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system. After removing the service grip from the FC stack assembly, store it in a safe location and use the "HIGH-VOLTAGE, DO NOT TOUCH" sign to notify other technicians that you are working on the high-voltage system
| *a | Without waiting for 10 minutes |
After removal of the service plug grips of both FC stack assembly and EV battery, wait for at least 10 minutes before touching the high-voltage connectors and terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
At least 10 minutes are necessary to discharge the high-voltage capacitors inside the inverter with converter assembly and FC stack assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
When reinstalling the service plug grip to the FC stack assembly or the EV battery, slide the lever of the service plug until the letters "UNLOCK" are completely hidden, and insert it firmly.
When the vehicle is parked with the power switch off, if the FC control ECU judges that the FC stack temperature will go below 0°C (32°F), it activates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds and drains water from the FC stack assembly. When performing inspection or repairs with the power switch off (not on (IG) or on (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work (If the auxiliary battery voltage is needed to conduct inspection, warm up the FC system beforehand).
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
While referring to the vehicle conditions stored in the freeze frame data, drive the vehicle in an urban area for approximately 10 minutes.
PROCEDURE
CHECK DTC OUTPUT (EV)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / EV / Trouble Codes.
Check for DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Microcomputer malfunction | P0A1B-168, 192, 193, 198, 661, 786, 794, 795, 796 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | EV Control Module | |
| Power source circuit malfunction | P0A1B-163, 164, 511, 512 | Drive Motor "A" Control Module |
| Sensor and actuator circuit malfunction | P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance | |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low | |
| P1D75-450 | FC Air Compressor Motor "A" Position Sensor Circuit | |
| P1D76-450 | FC Air Compressor Motor "A" Position Sensor Circuit Range/Performance | |
| P1D77-450 | FC Air Compressor Motor "A" Position Sensor Circuit Low | |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current | |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current | |
| P1D80 (all INF codes)*1 | FC Air Compressor Motor "A" Phase V Current | |
| P1D81 (all INF codes)*1 | FC Air Compressor Motor "A" Phase W Current | |
| System malfunction | P0AA6-526 | EV Battery Voltage System Isolation Fault |
| P0A78-113, 118, 119, 120, 128, 266, 267, 279, 284, 286, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808 | Drive Motor "A" Inverter Performance | |
| P1D82-459, 460, 461, 462, 463, 464, 465, 466, 467, 468, 469 | FC Air Compressor Motor Inverter Circuit | |
| P0A90-509 | Drive Motor "A" Performance | |
| P1D7F-472 | FC Air Compressor Speed Control Performance | |
| P0A94-124, 125, 126, 169, 170, 171, 172, 442, 547, 548, 549, 553, 554, 555, 556, 557, 585, 587, 589, 590 | Boosting Converter Performance | |
| P0C76-523 | EV Battery System Discharge Time Too Long | |
| P1E0D-450 | FC Converter Fail Signal Circuit High | |
Tech Tips
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0A94-172 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK DTC OUTPUT (FCDC)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / FCDC / Trouble Codes.
Check for DTCs.
| Result | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Tech Tips
P0A94-127 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the power switch off.
| B |
|
GO TO DTC CHART (FCDC SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed to FC stack assembly and EV battery.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connection condition of the low voltage connector of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK FC AIR COMPRESSOR RESOLVER CIRCUIT
Tech Tips
If the "FC Air Compressor Resolver Circuit" inspection results are normal, perform the next step.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHECK MOTOR RESOLVER CIRCUIT
Tech Tips
If the "Motor Resolver Circuit" inspection results are normal, perform the next step.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHECK FC AIR COMPRESSOR HIGH-VOLTAGE CIRCUIT
Tech Tips
If the "FC Air Compressor High-voltage Circuit" inspection results are normal, perform the next step.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHECK MOTOR HIGH-VOLTAGE CIRCUIT
Tech Tips
If the "Motor High-voltage Circuit" inspection results are normal, perform the next step.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHECK INVERTER LOW-VOLTAGE CIRCUIT
Tech Tips
If the "Inverter Low-voltage Circuit" inspection results are normal, perform the next step.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHECK CONNECTOR CONNECTION CONDITION (FC CONVERTER ASSEMBLY LOW-VOLTAGE CONNECTOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed to FC stack assembly and EV battery.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connection condition of the FC converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK FC STACK SERVICE PLUG GRIP (CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Visually check the connection of the FC stack service plug grip to the FC stack assembly. Remove the FC stack service plug grip and check for contamination.
| OK |
|---|
| Dirt or foreign matter has not entered the connectors, and there is no evidence of contamination. |
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE FC STACK SERVICE PLUG GRIP Click here |
| OK |
|
INSPECT FC STACK SERVICE PLUG GRIP
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE FC STACK SERVICE PLUG GRIP Click here |
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (FC CONVERTER POWER OUTLET CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed to FC stack assembly and EV battery.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Tech Tips
Make sure that no foreign matter, coolant or water has entered the inverter assembly with converter. Confirm that the inverter coolant volume has not increased.
Check that the bolts for the FC converter power outlet cable are tightened to the specified torque, the FC converter power outlet cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T = 8.0 N*m (82 kgf*cm, 6 ft.*lbf) |
Disconnect the FC converter power outlet cable from the inverter with converter assembly.
Check for arc marks at the terminals for the FC converter power outlet cable.
| Result | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Reconnect the FC converter power outlet cable to the inverter with converter assembly.
Install the inverter terminal cover to the inverter with converter assembly.
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK FC CONVERTER ASSEMBLY (FC CONVERTER POWER OUTLET CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed to FC stack assembly and EV battery.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the front FC converter service hole cover from the FC converter assembly.
Check that the bolts for the FC converter power outlet cable are tightened to the specified torque, the FC converter power outlet cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T = 8.0 N*m (82 kgf*cm, 6 ft.*lbf) |
Disconnect the FC converter power outlet cable from the FC converter assembly.
Check for arc marks at the terminals for the FC converter power outlet cable.
| Result | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Reconnect the FC converter power outlet cable to the FC converter assembly.
Install the front FC converter service hole cover to the FC converter assembly.
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK FC CONVERTER POWER OUTLET CABLE
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed to FC stack assembly and EV battery.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Tech Tips
Make sure that no foreign matter, coolant or water has entered the inverter assembly with converter. Confirm that the inverter coolant volume has not increased.
Disconnect the FC converter power outlet cable from the inverter with converter assembly.
Remove the front FC converter service hole cover from the FC converter assembly.
Disconnect the FC converter power outlet cable from the FC converter assembly.
| *1 | FC Converter Power Outlet Cable (Inverter with Converter Assembly Side) |
| *2 | FC Converter Power Outlet Cable (FC Converter Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
Reconnect the FC converter power outlet cable.
Install the front FC converter service hole cover to the FC converter assembly.
Remove the inverter terminal cover to the inverter with converter assembly.
| NG |
|
REPLACE FC CONVERTER POWER OUTLET CABLE Click here |
| OK |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY
| Result | ||
|---|---|---|
|
| NEXT |
|
CLEAR DTC
| Result | ||
|---|---|---|
|
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / EV / Trouble Codes.
Read and record the DTCs and freeze frame data.
Clear the DTCs and freeze frame data.
Turn the power switch off and wait 3 minutes or more.
| Result | ||
|---|---|---|
|
| NEXT |
|
SIMULATION TEST
Turn the power switch on (READY).
While referring to the vehicle conditions stored in the freeze frame data, drive the vehicle in an urban area for approximately 10 minutes.
CAUTION:
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
Connect the GTS to the DLC3.
Enter the following menus: Powertrain / EV / Trouble Codes.
Check for DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| A |
|
REPLACE FC CONVERTER ASSEMBLY Click here |
| B |
|
COMPLETED |