PROCEDURE
INSTALL NO. 2 ECM BRACKET
Install the No. 2 ECM bracket with the 2 screws.
INSTALL NO. 1 ECM BRACKET
Install the No. 1 ECM bracket with the 2 screws.
INSTALL ECM
Install the ECM with the 3 bolts.
Connect the 2 ECM connectors and move the 2 levers as shown in the illustration.
Note
When connecting a connector, make sure that dirt, water and other foreign matter is not stuck between the connector and ECM.
Make sure that the 2 levers are in the positions shown in the illustration.
INSTALL AIR CLEANER CASE SUB-ASSEMBLY
Install the air cleaner case sub-assembly with the 3 bolts.
Attach the wire harness clamp to the air cleaner case sub-assembly.
INSTALL AIR CLEANER CAP SUB-ASSEMBLY
INSTALL NO. 2 CYLINDER HEAD COVER
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
PERFORM INITIALIZATION
RESET MEMORY (for CVT)