AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) PROBLEM SYMPTOMS TABLE

Tech Tips


  • Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspected areas in the order they are listed. Replace parts as necessary.

  • Inspect the fuses and relays related to this system before inspecting the suspected areas below.

Air Conditioning System (for Manual Air Conditioning System)
Symptom Suspected Area Link
All functions of the air conditioning system do not operate IG power source circuit

Click here

Air conditioning amplifier assembly

Click here

Air flow control: No blower operation Blower motor circuit

Click here

Air conditioning amplifier assembly

Click here

Air flow control: No blower control Blower motor circuit

Click here

Air conditioning amplifier assembly

Click here

Air flow control: Insufficient air flow Blower motor circuit

Click here

Air conditioning amplifier assembly

Click here

Temperature control: Cooling effectiveness is poor Refrigerant shortage check using the GTS

Click here

Refrigerant volume -
Refrigerant pressure

Click here

Cooler expansion valve

Click here

Compressor assembly with pulley (for 1AD-FTV, 2AD-FHV, 2AD-CCo, 2AD-DPF)

Click here

Compressor assembly with pulley (for 2AR-FE)

Click here

Compressor assembly with pulley (for 3ZR-FAE, 3ZR-FE)

Click here

Air conditioning amplifier assembly

Click here

Temperature control: No cool air comes out Refrigerant shortage check using the GTS

Click here

Refrigerant volume -
Refrigerant pressure

Click here

Air mix damper control cable sub-assembly

Click here

Heater control switch circuit

Click here

Air conditioning pressure sensor circuit

Click here

Compressor solenoid circuit

Click here

Evaporator temperature sensor circuit

Click here

Ambient temperature sensor circuit

Click here

Cooler expansion valve

Click here

Air conditioning amplifier assembly

Click here

ECM (for 1AD-FTV)

Click here

ECM (for 2AD-FHV)

Click here

ECM (for 2AD-CCo, 2AD-DPF)

Click here

ECM (2AR-FE)

Click here

ECM (3ZR-FAE)

Click here

ECM (3ZR-FE)

Click here

Temperature control: No warm air comes out Air mix damper control cable sub-assembly

Click here

Heater control switch circuit

Click here

Ambient temperature sensor circuit

Click here

Air conditioning amplifier assembly

Click here

ECM (for 1AD-FTV)

Click here

ECM (for 2AD-FHV)

Click here

ECM (for 2AD-CCo, 2AD-DPF)

Click here

ECM (2AR-FE)

Click here

ECM (3ZR-FAE)

Click here

ECM (3ZR-FE)

Click here

Temperature control: Output air is warmer or cooler than the set temperature or response is slow Refrigerant shortage check using the GTS

Click here

Refrigerant volume -
Refrigerant pressure

Click here

Air mix damper control cable sub-assembly

Click here

Compressor solenoid circuit

Click here

Ambient temperature sensor circuit

Click here

Heater radiator unit sub-assembly

Click here

Cooler expansion valve

Click here

Air conditioning amplifier assembly

Click here

ECM (for 1AD-FTV)

Click here

ECM (for 2AD-FHV)

Click here

ECM (for 2AD-CCo, 2AD-DPF)

Click here

ECM (2AR-FE)

Click here

ECM (3ZR-FAE)

Click here

ECM (3ZR-FE)

Click here

Temperature control: No temperature control (only Max. cold or Max. hot) Heater control switch circuit

Click here

Air mix damper control cable sub-assembly

Click here

Ambient temperature sensor circuit

Click here

Evaporator temperature sensor circuit

Click here

Air conditioning amplifier assembly

Click here

No air inlet control Recirculation damper servo motor circuit

Click here

Air conditioning amplifier assembly

Click here

No air flow mode control No. 1 heater control sub-assembly

Click here

No. 2 heater control cable sub-assembly

Click here

Diagnostic trouble codes (DTCs) are not recorded. Set mode is cleared when the ignition switch is turned off. Air conditioning amplifier assembly

Click here