GENERATOR REMOVAL

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. REMOVE NO. 1 ENGINE UNDER COVER

    Click here

  4. REMOVE REAR ENGINE UNDER COVER RH

    Click here

  5. REMOVE NO. 2 CYLINDER HEAD COVER

    Click here

  6. REMOVE V-RIBBED BELT

    Click here

  7. REMOVE GENERATOR ASSEMBLY


    1. A01V981

      Remove the terminal cap.

    2. Remove the nut and disconnect the wire harness from terminal B.

    3. Disconnect the connector and detach the wire harness clamp.

    4. A01V6RA

      Remove the 3 bolts, No. 2 generator bracket and generator assembly.

    5. A01VB51

      Remove the bolt and wire harness clamp bracket.