MANIFOLD ABSOLUTE PRESSURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL VACUUM SENSOR ASSEMBLY


    1. Connect the No. 1 air hose to the vacuum sensor assembly.

    2. Install the vacuum sensor assembly with the bolt.

      Torque:
      5.0 N*m  { 51 kgf*cm, 44 in.*lbf }
    3. Connect the vacuum sensor assembly connector.

  2. INSTALL NO. 2 CYLINDER HEAD COVER

    Click here