| DTC Code | DTC Name |
|---|---|
| P0905 | Gate Select Position Circuit Range / Performance |
| P0906 | Gate Select Position Circuit Low |
| P0907 | Gate Select Position Circuit High |
DESCRIPTION
The select stroke sensor is mounted on the shift and select actuator, and detects the select position of the shift and select lever shaft. The sensor consists of a sensor arm, magnetic yoke and 2 Hall ICs. This sensor is a non-contact type, and uses Hall-effect elements (Hall ICs: main and sub), in order to yield accurate signals.
When the shift and select actuator is operating in the select direction, the magnetic yoke that is coaxially positioned on the sensor arm is rotated and the magnet position changes. The Hall ICs convert the magnet position change into voltage signals and send them to the TCM. The TCM judges the select motor operating condition (which gear shift fork shaft is selected: No. 1, No. 2, No. 3 or reverse) based on the signal from the select stroke sensor.
| *a | Shift and Select Actuator Operation |
| *b | Shift Direction |
| *c | Select Direction |
The main and sub circuits in the select stroke sensor have the same output characteristics. The sensor construction and operation of the select stroke sensor are basically the same as those of the clutch stroke sensor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | Memory |
|---|---|---|---|---|---|---|
| P0905 | Gate Select Position Circuit Range / Performance | Deviation between sensor signal 1 (main) and sensor signal 2 (sub) is 2.0 mm (0.078 in.) or more for 1.0 second or more (1-trip detection logic) |
|
Does not come on | Comes on | DTC stored |
| P0906 | Gate Select Position Circuit Low |
|
|
Comes on | Comes on | DTC stored |
| P0907 | Gate Select Position Circuit High |
|
|
Comes on | Comes on | DTC stored |
WIRING DIAGRAM
| *a | Sub |
| *b | Main |
| *c | Select Stroke Sensor |
CAUTION / NOTICE / HINT
Note
When installing parts related to the multi-mode manual transaxle system, perform the initialization and learning and synchronization position calibration procedures. In addition, the required operations differ according to the parts to be installed. Proceed with the operation in the order shown in the table below.
| Part Installed | Operation Order | See Procedure |
|---|---|---|
|
1. Initialization and learning of multi-mode manual transaxle system | |
| 2. Synchronization position calibration | ||
|
1. Initialization and learning of multi-mode manual transaxle system |
If the sensor or actuator is installed without the initialization and learning procedures, it may cause driving performance degradation or system component breakage.
PROCEDURE
INSPECT TCM (VCL1 AND VCL2 VOLTAGE)
Disconnect the select stroke sensor connector.
| *a | Front view of wire harness connector (to Select Stroke Sensor) |
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (SELECT STROKE SENSOR - TCM) Click here |
| OK |
|
INSPECT SELECT STROKE SENSOR
Remove the select stroke sensor.
| *a | Sensor Arm |
| *b | Component without harness connected (Select Stroke Sensor) |
| *c | Main |
Measure the voltage between the terminals of the select stroke sensor connector (main).
Prepare 3 dry cell batteries (1.5 V) and 2 leads for connecting the batteries and the sensor.
Connect the batteries in series.
Connect the positive battery terminal to sensor terminal 4 (VCL1), and the negative battery terminal to sensor terminal 5 (E2L1).
Measure the voltage according to the value(s) in the table below.
| Standard Voltage (combined dry cell battery voltage of 4.5 V) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
| Reference Voltage (combined dry cell battery voltage of 5.0 +/- 0.3 V) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
| *a | Sensor Arm |
| *b | Component without harness connected (Select Stroke Sensor) |
| *c | Sub |
Measure the voltage between the terminals of the select stroke sensor connector (sub).
Connect the positive battery terminal to sensor terminal 1 (VCL2), and the negative battery terminal to sensor terminal 2 (E2L2).
Measure the voltage according to the value(s) in the table below.
| Standard Voltage (combined dry cell battery voltage of 4.5 V) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
| Reference Voltage (combined dry cell battery voltage of 5.0 +/- 0.3 V) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Do not apply more than 6 V.
Do not use a sensor which has been dropped.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE SELECT STROKE SENSOR Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (SELECT STROKE SENSOR - TCM)
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE TCM
Replace the TCM.
| Result | ||
|---|---|---|
|
| NEXT |
|
PERFORM INITIALIZATION Click here |
REPLACE SELECT STROKE SENSOR
Replace the select stroke sensor.
| Result | ||
|---|---|---|
|
| NEXT |
|
PERFORM INITIALIZATION Click here |
CHECK HARNESS AND CONNECTOR (SELECT STROKE SENSOR - TCM)
Disconnect the TCM Connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE TCM
Replace the TCM.
| Result | ||
|---|---|---|
|
| NEXT |
|
PERFORM INITIALIZATION Click here |