PROCEDURE
INSTALL ECM
Install the No. 2 ECM bracket to the ECM with the 2 screws.
Install the No. 1 ECM bracket to the ECM with the 2 screws.
Install the ECM with bracket with the 2 bolts.
Connect the 2 ECM connectors and lower the 2 levers.
Note
When connecting the ECM connector, make sure that dirt, water or other foreign matter is not stuck between the ECM connector and ECM.
Make sure that the 2 levers are securely lowered.
CONNECT NO. 1 AIR CLEANER INLET
Connect the No. 1 air cleaner inlet with the bolt.
INSTALL AIR CLEANER CASE SUB-ASSEMBLY
INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
INSTALL AIR CLEANER CAP SUB-ASSEMBLY WITH AIR CLEANER HOSE ASSEMBLY
INSTALL RADIATOR SUPPORT OPENING COVER
INSTALL NO. 1 ENGINE COVER
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
PERFORM REGISTRATION
PERFORM INITIALIZATION