HEATED OXYGEN SENSOR INSTALLATION

CAUTION / NOTICE / HINT

Tech Tips

Perform "Inspection After Repairs" after replacing the heated oxygen sensor Click here.

PROCEDURE


  1. INSTALL HEATED OXYGEN SENSOR


    1. A000RPFE02
      Text in Illustration
      *1 Fulcrum Length

      for Bank 2 Sensor 2:

      Using SST, install the heated oxygen sensor.

      SST
      09224-00011
      Torque:
      without SST
      44 N*m  { 449 kgf*cm, 32 ft.*lbf }
      with SST
      40 N*m  { 408 kgf*cm, 30 ft.*lbf }

      Tech Tips


      • Use a torque wrench with a fulcrum length of 300 mm (11.8 in.). When using a torque wrench with a fulcrum length that is not 300 mm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification Click here.

      • Make sure SST and the wrench are connected in a straight line.

      • Perform "Inspection After Repairs" after replacing the heated oxygen sensor Click here.

    2. A000ORCE02
      Text in Illustration
      *1 Fulcrum Length

      for Bank 1 Sensor 2:

      Using SST, install the heated oxygen sensor.

      SST
      09224-00011
      Torque:
      without SST
      44 N*m  { 449 kgf*cm, 32 ft.*lbf }
      with SST
      40 N*m  { 408 kgf*cm, 30 ft.*lbf }

      Tech Tips


      • Use a torque wrench with a fulcrum length of 300 mm (11.8 in.). When using a torque wrench with a fulcrum length that is not 300 mm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification Click here.

      • Make sure SST and the wrench are connected in a straight line.

      • Perform "Inspection After Repairs" after replacing the heated oxygen sensor Click here.

    3. Pass the heated oxygen sensor connector through the floor panel and install the grommet.

  2. CONNECT HEATED OXYGEN SENSOR CONNECTOR


    1. for Bank 1 Sensor 2:

      Connect the heated oxygen sensor connector.

    2. for Bank 2 Sensor 2:

      Connect the heated oxygen sensor connector.

  3. INSTALL INSTRUMENT PANEL FINISH PANEL END RH

    Click here

  4. INSPECT FOR EXHAUST GAS LEAK