LIGHTING SYSTEM, Diagnostic DTC:B1244

DTC Code DTC Name
B1244 Light Sensor Circuit Malfunction

DESCRIPTION

The automatic light control sensor detects the ambient light. The sensor creates an electrical signal based on the amount of light, and sends the signal to the main body ECU (multiplex network body ECU). The main body ECU (multiplex network body ECU) turns on or off the headlights and taillights/rear side marker lights according to the signal.

DTC No. DTC Detecting Condition Trouble Area
B1244
  • Malfunction in automatic light control sensor

  • Open or short in automatic light control sensor circuit


  • Automatic light control sensor

  • Harness or connector

  • Main body ECU (multiplex network body ECU)

WIRING DIAGRAM

A01I0J9E09

INSPECTION PROCEDURE

PROCEDURE


  1. READ VALUE USING TECHSTREAM


    1. Connect the Techstream to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the Techstream on.

    4. Enter the following menus: Body Electrical / Main Body / Data List.

    5. Read the display on the Techstream.

      Main Body
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Illumination Rate info Illumination rate information/0.00 ms to 2162.65 ms Value is output according to ambient light levels -
      OK
      Normal condition listed above is displayed.

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - AUTOMATIC LIGHT CONTROL SENSOR)


    1. Disconnect the I61*1, I185*2 or I184*3 automatic light control sensor connector.

    2. Disconnect the I13 main body ECU (multiplex network body ECU) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for Automatic Air Conditioning System, 10 Speaker
      Tester Connection Condition Specified Condition
      I13-22 (CLTE) - I61-3 (CLTE) Always Below 1 Ω
      I13-21 (CLTS) - I61-5 (CLTS) Always Below 1 Ω
      I13-20 (CLTB) - I61-6 (CLTB) Always Below 1 Ω
      I13-22 (CLTE) - Body ground Always 10 kΩ or higher
      I13-21 (CLTS) - Body ground Always 10 kΩ or higher
      I13-20 (CLTB) - Body ground Always 10 kΩ or higher
      for Manual Air Conditioning System, 6 Speaker
      Tester Connection Condition Specified Condition
      I13-22 (CLTE) - I185-5 (CLTE) Always Below 1 Ω
      I13-21 (CLTS) - I185-4 (CLTS) Always Below 1 Ω
      I13-20 (CLTB) - I185-3 (CLTB) Always Below 1 Ω
      I13-22 (CLTE) - Body ground Always 10 kΩ or higher
      I13-21 (CLTS) - Body ground Always 10 kΩ or higher
      I13-20 (CLTB) - Body ground Always 10 kΩ or higher
      for Automatic Air Conditioning System, 6 Speaker
      Tester Connection Condition Specified Condition
      I13-22 (CLTE) - I184-3 (CLTE) Always Below 1 Ω
      I13-21 (CLTS) - I184-5 (CLTS) Always Below 1 Ω
      I13-20 (CLTB) - I184-6 (CLTB) Always Below 1 Ω
      I13-22 (CLTE) - Body ground Always 10 kΩ or higher
      I13-21 (CLTS) - Body ground Always 10 kΩ or higher
      I13-20 (CLTB) - Body ground Always 10 kΩ or higher

      • *1: for Automatic Air Conditioning System, 10 Speaker

      • *2: for Manual Air Conditioning System, 10 Speaker

      • *3 for Automatic Air Conditioning System, 6 Speaker


    NG
    OK
  3. INSPECT MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)


    1. A01HY0VE02
      Text in Illustration
      *a

      Component with harness connected

      (Main Body ECU (Multiplex Network Body ECU))

      Reconnect the I13 main body ECU (multiplex network body ECU) connector.

    2. Measure the voltage and resistance according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      I13-20 (CLTB) - I13-22 (CLTE) Ignition switch off Below 1 V
      Ignition switch ON 11 to 14 V
      Standard Resistance
      Tester Connection Condition Specified Condition
      I13-22 (CLTE) - Body ground Always Below 1 Ω

    NG
    OK
  4. INSPECT AUTOMATIC LIGHT CONTROL SENSOR


    1. for Automatic Air Conditioning System


      1. Reconnect the I61*1 or I184*2 automatic light control sensor connector.

        A01I1NDE11
      2. Connect an oscilloscope to the automatic light control sensor connector.

        Text in Illustration
        *A 10 Speaker
        *B 6 Speaker
        *a

        Component with harness connected

        (Automatic Light Control Sensor)

      3. Check the waveform.

        OK
        Tester Connection Tool Setting Condition Specified Condition
        I61-3 (CLTE) - I61-5 (CLTS) 5 V/DIV., 5 ms./DIV. Ignition switch ON, light control switch in AUTO position Correct waveform is as shown
        I184-3 (CLTE) - I184-5 (CLTS) 5 V/DIV., 5 ms./DIV. Ignition switch ON, light control switch in AUTO position Correct waveform is as shown
        A01HZ11E01

        Tech Tips

        If the ambient light becomes brighter, width (A) becomes narrower.


        • *1: 10 Speaker

        • *2: 6 Speaker

    2. for Manual Air Conditioning System


      1. Reconnect the I185 automatic light control sensor connector.

        A01HZ57E07
      2. Connect an oscilloscope to the automatic light control sensor connector.

        Text in Illustration
        *a

        Component with harness connected

        (Automatic Light Control Sensor)

      3. Check the waveform.

        OK
        Tester Connection Tool Setting Condition Specified Condition
        I185-5 (CLTE) - I185-4 (CLTS) 5 V/DIV., 5 ms./DIV. Ignition switch ON, light control switch in AUTO position Correct waveform is as shown
        A01HZ11E01

        Tech Tips

        If the ambient light becomes brighter, width A becomes narrower.


    NG
    OK