AUDIO AND VISUAL SYSTEM(for Radio and Display Type) AVC-LAN Circuit

DESCRIPTION

Each audio system component connected to the AVC-LAN (communication bus) transfers switch signals using the audio visual communication local area network.

If a short to +B or short to ground occurs in the AVC-LAN, the audio system will not function normally because communication is not possible.

WIRING DIAGRAM

B001Y83E02

CAUTION / NOTICE / HINT

Tech Tips


  • The radio and display receiver assembly is the master unit.

  • When replacing the radio and display receiver assembly, it is necessary to perform the vehicle contract setting for Connected Services (w/ Connected Services Function).

PROCEDURE


  1. INSPECT RADIO AND DISPLAY RECEIVER ASSEMBLY


    1. Remove the radio and display receiver assembly Click here.

      B001XH4E01
      Text in Illustration
      *A w/ Side Monitor System - -
      *a

      Component without harness connected

      (Radio and Display Receiver Assembly)

      - -
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      7 (TX1+) - 8 (TX1-) Always 60 to 80 Ω
      7 (TX3+) - 8 (TX3-)* Always 60 to 80 Ω

      • *: w/ Side Monitor System


    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (AVC-LAN CIRCUIT)


    • *: w/ Side Monitor System


    1. Disconnect the F118 and F124 radio and display receiver assembly connectors.

    2. Disconnect the F18 stereo component amplifier assembly connector.

    3. Disconnect the F75 parking assist ECU connector*.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F118-7 (TX3+) - F75-11 (TX+)* Always Below 1 Ω
      F118-8 (TX3-) - F75-10 (TX-)* Always Below 1 Ω
      F124-7 (TX1+) - F18-8 (TX+) Always Below 1 Ω
      F124-8 (TX1-) - F18-7 (TX-) Always Below 1 Ω
      F118-7 (TX3+) - Body ground* Always 10 kΩ or higher
      F118-8 (TX3-) - Body ground* Always 10 kΩ or higher
      F124-7 (TX1+) - Body ground Always 10 kΩ or higher
      F124-8 (TX1-) - Body ground Always 10 kΩ or higher

    NG
    OK
  3. INSPECT MALFUNCTIONING PARTS


    1. Disconnect and reconnect each slave unit one by one until the master unit returns to normal operation.

      Tech Tips


      • Check all slave units.

      • When disconnecting a slave unit causes the master unit to return to normal operation, this indicates that the slave unit is malfunctioning. Replace the malfunctioning slave unit.

      OK
      Master unit returns to normal operation.

    OK
    NG