AIR CONDITIONING PRESSURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL AIR CONDITIONING PRESSURE SENSOR


    1. Apply a sufficient amount of compressor oil to a new air conditioning pressure sensor.

      Compressor oil
      ND-OIL 11 or equivalent

      Note


      • Keep the O-ring and O-ring fitting surfaces free from dirt or foreign matter.

      • Do not use any compressor oil other than ND-OIL 11 or equivalent. If any compressor oil other than ND-OIL 11 or equivalent is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.

    2. Install the new air conditioning pressure sensor.

      Torque:
      11 N*m  { 110 kgf*cm, 8 ft.*lbf }

      Note


      • Do not deform the piping.

      • Make sure to confirm that the piping does not disengage from the plastic clamp.

    3. Connect the connector.

  2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  3. INSTALL REAR FLOOR BOARD UPPER NO. 3 PLATE

    Click here

  4. INSTALL DECK FLOOR BOX RH

    Click here

  5. INSTALL REAR NO. 3 FLOOR BOARD

    Click here

  6. INSTALL REAR DECK FLOOR BOX

    Click here

  7. INSTALL REAR NO. 2 FLOOR BOARD

    Click here

  8. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT (for HFC-134a(R134a))

    Click here

  9. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT (for HFO-1234yf(R1234yf))

    Click here

  10. WARM UP COMPRESSOR (for HFC-134a(R134a))

    Click here

  11. WARM UP COMPRESSOR (for HFO-1234yf(R1234yf))

    Click here

  12. INSPECT FOR REFRIGERANT LEAK (for HFC-134a(R134a))

    Click here

  13. INSPECT FOR REFRIGERANT LEAK (for HFO-1234yf(R1234yf))

    Click here