CAUTION / NOTICE / HINT
Note
Make sure the combination meter glass and meter display panel does not become dirty with fingerprints, oil, etc. If dirty, clean with a soft cloth.
Be careful of static electricity when handling the meter ECU and meter display panel. Make sure the work area has static electricity prevention measures.
CAUTION:
Do not touch any parts of the circuit of the meter display panel and condenser. Even if the engine switch is off, the meter display panel and condenser are electrically charged.
Tech Tips
Use the same procedure for RHD and LHD vehicles.
The procedure listed below is for LHD vehicles.
PROCEDURE
REMOVE COWL TOP VENTILATOR LOUVER
PRECAUTION
Note
After turning the engine switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work Click here.
DISABLE AUTOAWAY/RETURN FUNCTION
Disable the autoaway/return function by changing the customize parameter Click here.
Note
Record the current customize parameter setting (whether the autoaway/return function is enabled or disabled) in order to restore the current setting after finishing the operation.
Tech Tips
Performing the above operation causes the autoaway/return function to be disabled when the engine switch is turned off.
Turn the engine switch on (IG). Operate the tilt and telescopic switch to fully retract and tilt up the steering column assembly.
Turn the engine switch off.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Disconnect the cable from the negative (-) battery terminal.
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
REMOVE INSTRUMENT SIDE PANEL LH
REMOVE INSTRUMENT PANEL ORNAMENT
REMOVE NO. 1 INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY
REMOVE NO. 2 INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY
| *1 | Protective Tape |
Apply protective tape to the area shown in the illustration.
Remove the 2 clips.
Detach the 6 clips and remove the No. 2 instrument cluster finish panel sub-assembly.
Disconnect the 2 connectors.
REMOVE STEERING COLUMN COVER (w/o Driver Monitor Camera)
REMOVE STEERING COLUMN COVER (w/ Driver Monitor Camera)
REMOVE COMBINATION METER ASSEMBLY
Remove the 4 screws and combination meter assembly.
Detach the 2 claws and open the connector cover.