PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
REMOVE COWL TOP VENTILATOR LOUVER
PRECAUTION
Note
After turning the engine switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
REMOVE EXHAUST MANIFOLD SUB-ASSEMBLY LH
for 1UR-FE: Click here
for 1UR-FSE: Click here
DISCONNECT SUCTION TUBE SUB-ASSEMBLY B
Remove the bolt and disconnect the suction tube sub-assembly B from the with pulley compressor assembly.
Remove the O-ring from the cooler refrigerant suction tube sub-assembly B.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.
DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the discharge hose sub-assembly from the with pulley compressor assembly.
Remove the O-ring from the discharge hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.
REMOVE WITH PULLEY COMPRESSOR ASSEMBLY
Disconnect the connector.
Remove the 2 bolts and 2 nuts.
Using an E8 "TORX" socket wrench, remove the 2 stud bolts and with pulley compressor assembly.