ECM INSTALLATION

PROCEDURE


  1. INSTALL ECM


    1. A001AT9

      Install the ECM with the 2 nuts.

      Torque:
      5.5 N*m  { 56 kgf*cm, 49 in.*lbf }
    2. Connect the 6 ECM connectors.

  2. CONNECT NO. 2 CONNECTOR HOLDER


    1. A0019L3E04
      *1 Connector Holder

      Attach the 2 claws to connect the connector holder.

    2. Connect the 2 engine wire connectors.

  3. INSTALL TCM


    1. A0019VZ

      Install the TCM with the 2 nuts.

      Torque:
      5.5 N*m  { 56 kgf*cm, 49 in.*lbf }
    2. Connect the 4 TCM connectors.

  4. INSTALL ENGINE ROOM ECU COVER


    1. A001EJ1

      Install the engine room ECU cover with the 3 bolts.

      Torque:
      5.5 N*m  { 56 kgf*cm, 49 in.*lbf }
  5. INSTALL ENGINE ROOM SIDE COVER LH

    Click here

  6. INSTALL AIR CLEANER INLET COVER SUB-ASSEMBLY

    Click here

  7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  8. INSTALL COWL TOP VENTILATOR LOUVER

    Click here

  9. PERFORM RESET MEMORY

    Note

    Perform the RESET MEMORY (AT initialization) when replacing the automatic transmission assembly, engine assembly or ECM.


    Tech Tips

    Initialization cannot be completed by only removing the battery.

  10. SHIFT CONTROL SYNCHRONIZATION (for Sport Package)

    Click here