CAN COMMUNICATION SYSTEM, Diagnostic DTC:U1002

DTC Code DTC Name
U1002 Lost Communication with Gateway Module (Power Management2)

DESCRIPTION


DTC Code DTC Detection Condition Trouble Area
U1002 Lost communication with the gateway module (Power Management2).
  • Power management bus circuit

  • Air conditioning amplifier assembly CAN branch wire or connector*

  • Power management control ECU CAN main wire or connector

  • ECM CAN main wire or connector

  • Air conditioning amplifier assembly*

  • Power management control ECU

  • ECM

  • No. 4 junction connector*


WIRING DIAGRAM

A004P65E04

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

Tech Tips

Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.


    NEXT
  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL


    1. Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the CAN main wire and the CAN branch wire.

      CAUTION:

      Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.

      Note

      When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.


    NEXT
  3. CHECK VEHICLE CONDITION


    1. Check the vehicle condition.

      Result
      Result Proceed to
      w/ Entry and Start System A
      w/o Entry and Start System B

    B
    A
  4. CHECK CAN BUS WIRE (CAN MAIN WIRE FOR DISCONNECTION, CHECK BUS LINE FOR SHORT CIRCUIT)


    1. A004T8SE02
      Text in Illustration
      *a

      Component with harness connected

      (Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition Resistance: Malfunction
      D111-12 (CA3P) - D111-11 (CA3N) Ignition switch off 54 to 69 Ω Below 54 Ω: Short in line
      D111-12 (CA3P) - D111-11 (CA3N) Ignition switch off 54 to 69 Ω Higher than 69 Ω: Open in CAN main bus line
      D111-12 (CA3P) - D111-2 (AM21) Ignition switch off 6 kΩ or higher Below 6 kΩ: +B short
      D111-11 (CA3N) - D111-2 (AM21) Ignition switch off 6 kΩ or higher Below 6 kΩ: +B short
      D111-12 (CA3P) - D111-6 (GND) Ignition switch off 200 Ω or higher Below 200 Ω: Ground short
      D111-11 (CA3N) - D111-6 (GND) Ignition switch off 200 Ω or higher Below 200 Ω: Ground short
      Result
      Result Proceed to

      NG


      • Open in CAN main bus line

      A

      NG


      • Short in line

      • +B short

      • GND short

      B
      OK C

    B
    C
    A
  5. CHECK FOR OPEN IN CAN BUS WIRE (NO. 4 JUNCTION CONNECTOR - ECM)


    1. A004O8NE02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to No. 4 Junction Connector)

      Disconnect the No. 4 junction connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D91-3 (CANH) - D91-14 (CANL) Ignition switch off 108 to 132 Ω

    NG
    OK
  6. CHECK FOR OPEN IN CAN BUS WIRE (NO. 4 JUNCTION CONNECTOR - POWER MANAGEMENT CONTROL ECU)


    1. A004U6TE02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to No. 4 Junction Connector)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D91-2 (CANH) - D91-13 (CANL) Ignition switch off 108 to 132 Ω

    OK
    NG
  7. CONNECT CONNECTOR


    1. Reconnect the D91 No. 4 junction connector.


    NEXT
  8. CHECK FOR OPEN IN CAN BUS WIRE (ECM - NO. 4 JUNCTION CONNECTOR)


    1. A004SUHE02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to ECM)

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A83-13 (CANP) - A83-12 (CANN) Ignition switch off 108 to 132 Ω
      Result
      Result Proceed to
      OK (for 1WW) A
      OK (for 2WW) B
      NG C

    A
    B
    C
  9. CONNECT CONNECTOR


    1. Reconnect the D91 No. 4 junction connector.


    NEXT
  10. CHECK FOR OPEN IN CAN BUS WIRE (POWER MANAGEMENT CONTROL ECU - NO. 4 JUNCTION CONNECTOR)


    1. A004P88E02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Disconnect the power management control ECU connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D111-12 (CA3P) - D111-11 (CA3N) Ignition switch off 108 to 132 Ω

    OK
    NG
  11. CHECK FOR SHORT IN CAN BUS WIRE (NO. 4 JUNCTION CONNECTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)


    1. A004TJ2E02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to No. 4 Junction Connector)

      *b Front view of DLC3

      Disconnect the No. 4 junction connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D91-1 (CANH) - D91-12 (CANL) Ignition switch off 200 Ω or higher
      D91-1 (CANH) - D8-4 (CG) Ignition switch off 200 Ω or higher
      D91-12 (CANL) - D8-4 (CG) Ignition switch off 200 Ω or higher
      D91-1 (CANH) - D8-16 (BAT) Ignition switch off 6 kΩ or higher
      D91-12 (CANL) - D8-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  12. CHECK FOR SHORT IN CAN BUS WIRE (NO. 4 JUNCTION CONNECTOR - ECM)


    1. A004MQ4E02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to No. 4 Junction Connector)

      *b Front view of DLC3

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D91-3 (CANH) - D91-14 (CANL) Ignition switch off 108 to 132 Ω
      D91-3 (CANH) - D8-4 (CG) Ignition switch off 200 Ω or higher
      D91-14 (CANL) - D8-4 (CG) Ignition switch off 200 Ω or higher
      D91-3 (CANH) - D8-16 (BAT) Ignition switch off 6 kΩ or higher
      D91-14 (CANL) - D8-16 (BAT) Ignition switch off 6 kΩ or higher

    NG
    OK
  13. CHECK FOR SHORT IN CAN BUS WIRE (NO. 4 JUNCTION CONNECTOR - POWER MANAGEMENT CONTROL ECU)


    1. A004NDGE02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to No. 4 Junction Connector)

      *b Front view of DLC3

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D91-2 (CANH) - D91-13 (CANL) Ignition switch off 108 to 132 Ω
      D91-2 (CANH) - D8-4 (CG) Ignition switch off 200 Ω or higher
      D91-13 (CANL) - D8-4 (CG) Ignition switch off 200 Ω or higher
      D91-2 (CANH) - D8-16 (BAT) Ignition switch off 6 kΩ or higher
      D91-13 (CANL) - D8-16 (BAT) Ignition switch off 6 kΩ or higher

    OK
    NG
  14. CONNECT CONNECTOR


    1. Reconnect the D91 No. 4 junction connector.


    NEXT
  15. CHECK FOR SHORT IN CAN BUS WIRE (AIR CONDITIONING AMPLIFIER ASSEMBLY)


    1. A004TJXE02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Air Conditioning Amplifier Assembly)

      *b Front view of DLC3

      Disconnect the air conditioning amplifier assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D47-11 (CANH) - D47-12 (CANL) Ignition switch off 54 to 69 Ω
      D47-11 (CANH) - D8-4 (CG) Ignition switch off 200 Ω or higher
      D47-12 (CANL) - D8-4 (CG) Ignition switch off 200 Ω or higher
      D47-11 (CANH) - D8-16 (BAT) Ignition switch off 6 kΩ or higher
      D47-12 (CANL) - D8-16 (BAT) Ignition switch off 6 kΩ or higher

    OK
    NG
  16. CONNECT CONNECTOR


    1. Reconnect the D91 No. 4 junction connector.


    NEXT
  17. CHECK FOR SHORT IN CAN BUS WIRE (ECM)


    1. A004RPTE02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to ECM)

      *b Front view of DLC3

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A83-13 (CANP) - A83-12 (CANN) Ignition switch off 108 to 132 Ω
      A83-13 (CANP) - D8-4 (CG) Ignition switch off 200 Ω or higher
      A83-12 (CANN) - D8-4 (CG) Ignition switch off 200 Ω or higher
      A83-13 (CANP) - D8-16 (BAT) Ignition switch off 6 kΩ or higher
      A83-12 (CANN) - D8-16 (BAT) Ignition switch off 6 kΩ or higher
      Result
      Result Proceed to
      OK (for 1WW) A
      OK (for 2WW) B
      NG C

    A
    B
    C
  18. CONNECT CONNECTOR


    1. Reconnect the D91 No. 4 junction connector.


    NEXT
  19. CHECK FOR SHORT IN CAN BUS WIRE (POWER MANAGEMENT CONTROL ECU)


    1. A004TH8E02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      *b Front view of DLC3

      Disconnect the power management control ECU connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D111-12 (CA3P) - D111-11 (CA3N) Ignition switch off 108 to 132 Ω
      D111-12 (CA3P) - D8-4 (CG) Ignition switch off 200 Ω or higher
      D111-11 (CA3N) - D8-4 (CG) Ignition switch off 200 Ω or higher
      D111-12 (CA3P) - D8-16 (BAT) Ignition switch off 6 kΩ or higher
      D111-11 (CA3N) - D8-16 (BAT) Ignition switch off 6 kΩ or higher

    OK
    NG
  20. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BATTERY AND BODY GROUND)


    1. A004TU6E02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Connect the cable to the negative (-) battery terminal.

      Note

      When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

    2. Disconnect the power management control ECU connector.

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      D111-2 (AM21) - Body ground Always 11 to 14 V
      D111-1 (AM22) - Body ground Always 11 to 14 V
    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D111-6 (GND) - Body ground Always Below 1 Ω
      D111-5 (GND2) - Body ground Always Below 1 Ω

    OK
    NG
  21. CHECK FOR OPEN IN CAN BUS WIRE (POWER MANAGEMENT CONTROL ECU CAN MAIN WIRE)


    1. A004NB7E02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Disconnect the power management control ECU connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D104-4 (CA3P) - D104-3 (CA3N) Ignition switch off 108 to 132 Ω

    NG
    OK
  22. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BATTERY AND BODY GROUND)


    1. A004R30E02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Connect the cable to the negative (-) battery terminal.

      Note

      When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      D104-8 (AM21) - Body ground Always 11 to 14 V
      D104-2 (IG2) - Body ground Ignition switch ON 11 to 14 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D104-12 (GND) - Body ground Always Below 1 Ω

    OK
    NG