DESCRIPTION
The max hot bypass damper servo motor (for COOL) sends pulse signals to inform the air conditioning amplifier of the damper position. The air conditioning amplifier activates the motor (normal, reverse) based on the signals to move the max hot bypass damper servo motor (for COOL) to any position. As a result, when the air conditioner is operating, the temperature of the air blowing toward the driver's head area is controlled.
Tech Tips
Confirm that no mechanical problem is present because this diagnostic code can be output when either a damper link or damper is mechanically locked.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1493/93 | Max hot bypass damper servo motor (for COOL) position sensor value does not change even if air conditioning amplifier operates max hot bypass damper servo motor |
|
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
CHECK FOR DTC
Clear the DTCs Click here.
Check for DTCs Click here.
| Result | Proceed to |
|---|---|
| DTC B1493/93 is not output | A |
| DTC B1493/93 is output | B |
| DTC B1493/93 and B1497/97 are output | C |
| B |
|
READ VALUE USING INTELLIGENT TESTER (MAX HOT BYPASS DAMPER SERVO MOTOR TARGET PULSE (for COOL)) Click here |
| C |
|
GO TO DTC B1497/97 Click here |
| A |
|
USE SIMULATION METHOD TO CHECK Click here
READ VALUE USING INTELLIGENT TESTER (MAX HOT BYPASS DAMPER SERVO MOTOR TARGET PULSE (for COOL))
Use the Data List to check if the servo motor is functioning properly.
| Tester Display | Measurement Item / Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| M/H Bypass COOL Targ Pls | Max hot bypass servo motor COOL target pulse / for LHD Min.: 51, Max.: 63 for RHD Min.: 67, Max.: 78 |
for LHD:
for RHD:
|
- |
| OK |
|---|
| The display is as specified in the normal condition. |
Visually inspect the max hot bypass servo motor (for COOL).
Visually inspect whether the max hot bypass servo motor (for COOL) operates.
| OK |
|---|
| The max hot bypass servo motor (for COOL) operates. |
| Result | Proceed to |
|---|---|
| The Data List value changes and the max hot bypass servo motor (for COOL) operates (When troubleshooting according to the DTC output) | A |
| The Data List value changes and the max hot bypass servo motor (for COOL) operates (When troubleshooting according to Problem Symptoms Table) | B |
| The Data List value does not change and the max hot bypass servo motor (for COOL) does not operate | C |
| The Data List value changes, but the max hot bypass servo motor (for COOL) does not operate | D |
| B |
|
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
REPLACE AIR CONDITIONING AMPLIFIER Click here |
| D |
|
CHECK MAX HOT BYPASS SERVO MOTOR (for COOL) Click here |
| A |
|
CHECK FOR DTC
Clear the DTCs Click here.
Check for DTCs Click here.
| OK |
|---|
| DTC B1493/93 is not output. |
| NG |
|
REPLACE AIR CONDITIONING AMPLIFIER Click here |
| OK |
|
USE SIMULATION METHOD TO CHECK Click here
CHECK MAX HOT BYPASS SERVO MOTOR (for COOL)
Replace the max hot bypass servo motor Click here.
Tech Tips
Since the servo motor cannot be inspected while it is removed from the vehicle, replace the servo motor with a normal one.
Clear the DTCs Click here.
Check for DTCs Click here.
| OK |
|---|
| DTC B1493/93 is not output. |
| NG |
|
CHECK AIR CONDITIONING HARNESS Click here |
| OK |
|
END (MAX HOT BYPASS SERVO MOTOR (for COOL) IS FAULTY)
CHECK AIR CONDITIONING HARNESS
Replace the air conditioning harness Click here.
Clear the DTCs Click here.
Check for DTCs Click here.
| OK |
|---|
| DTC B1493/93 is not output. |
| NG |
|
REPLACE AIR CONDITIONING AMPLIFIER Click here |
| OK |
|
END (AIR CONDITIONING HARNESS IS FAULTY)