DESCRIPTION
For a description of the inverter, Click here.
If the generator inverter overheats, has a circuit malfunction, or has an internal short, the inverter transmits this information to the MG ECU via the generator inverter fail signal line.
If an abnormal amount of current flows through the generator inverter, the MG ECU detects it and sends a signal to inform the hybrid vehicle control ECU of the malfunction.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A7A | 122 | Generator inverter fail signal detection (overcurrent due to system malfunction) |
|
INSPECTION PROCEDURE
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
PROCEDURE
CHECK DTC OUTPUT (HV)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
GO TO DTC CHART Click here |
| A |
|
CHECK DTC OUTPUT (HV)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A1A (all INF codes) *1 | Generator Control Module |
| P0A1B (all INF codes) *1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes) *1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60 (all INF codes) *1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes) *1 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes) *1 | Generator Phase V Current |
| P0A75 (all INF codes) *1 | Generator Phase W Current |
| P0A78-266, 267, 279, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808 | Drive Motor "A" Inverter Performance |
| P0A7A-325, 344, 517, 518, 809, 810, 811 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590 | DC / DC Converter Performance |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P3004-803 | High Voltage Power Resource |
Tech Tips
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic flowchart.
P0A7A-122 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
| B |
|
GO TO DTC CHART Click here |
| A |
|
CHECK AMOUNT OF GASOLINE
Turn the power switch on (IG).
Check the amount of fuel by referring to the fuel gauge in the meter.
| OK |
|---|
| Adequate amount of fuel is in the tank. |
Tech Tips
If the vehicle is driven when there is no fuel in the tank, MG1 will crank the engine but the engine will not start. For this reason, an inoperative condition of MG1 may be detected.
Add fuel until the low fuel level warning light turns off.
| NG |
|
REFUEL VEHICLE |
| OK |
|
CHECK ENGINE START
Turn the power switch on (READY).
Check if the engine starts.
Tech Tips
Depressing the accelerator pedal with the shift lever in the P position will cause the engine to start.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
| A |
|
INSPECT CRANKSHAFT PULLEY REVOLUTION (P POSITION)
Turn the power switch off.
Move the shift lever to the P position and lift up the vehicle.
Turn the crankshaft pulley using hand tools to check if the crankshaft can rotate smoothly.
CAUTION:
Do not turn the power switch on (READY) while performing this inspection. Be sure to turn the power switch off before performing this inspection to prevent the engine from starting.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
| A |
|
INSPECT CRANKSHAFT PULLEY REVOLUTION (N POSITION)
Lower the vehicle.
Move the shift lever to the N position and lift up the vehicle.
Turn the crankshaft pulley using hand tools to check if the crankshaft can rotate smoothly.
CAUTION:
Do not turn the power switch on (READY) while performing this inspection. Be sure to turn the power switch off before performing this inspection to prevent the engine from starting.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here |
| A |
|
REPAIR OR REPLACE ENGINE
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Remove the service plug grip. Click here
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector cannot be pulled out.
Check the connection of the low voltage connector of the inverter with converter assembly.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
Tech Tips
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
CAUTION:
Be sure to wear insulated gloves.
Turn the power switch off.
Disconnect the low voltage connector from the inverter with converter assembly.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard voltage | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| RHD | |||||||||||||||||||||
|
Note
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK GENERATOR RESOLVER
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | ||||||||||||
|
||||||||||||
| RHD | ||||||||||||
|
| Standard resistance (Check for short) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | ||||||||||||
|
||||||||||||
| RHD | ||||||||||||
|
| NG |
|
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
Turn the power switch on (IG).
Disconnect the low voltage connector from the inverter with converter assembly.
Measure the voltage according to the value(s) in the table below.
| Standard voltage | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| RHD | |||||||||||||||||||||
|
Note
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK MOTOR RESOLVER
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | ||||||||||||
|
||||||||||||
| RHD | ||||||||||||
|
| Standard resistance (Check for short) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | ||||||||||||
|
||||||||||||
| RHD | ||||||||||||
|
| NG |
|
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Remove the inverter terminal cover from the inverter with converter assembly.
For LHD vehicles, use the following procedures Click here.
For RHD vehicles, use the following procedures Click here.
Note
Lift the inverter terminal cover horizontally so that it does not tilt. Failure to do so may break the inverter cover guide pins.
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m {82 kgf*cm, 71 in.*lbf} |
Note
Make sure that the tightening torque of the bolts is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Check for arc marks at the bolts for the generator cable.
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m {82 kgf*cm, 71 in.*lbf} |
Note
Make sure that the tightening torque of the bolts is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Check for arc marks at the bolts for the motor cable.
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MG1)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Disconnect the generator cable and motor cable from the inverter with converter assembly.
Tech Tips
For the removal and installation procedures related to the generator cable and motor cable, Click here for LHD, Click here for RHD).
Check MG1 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
Tech Tips
If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | ||||||||||||
|
||||||||||||
| RHD | ||||||||||||
|
Tech Tips
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68° F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (° C)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
| OK |
|
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MG2)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Disconnect the generator cable and motor cable from the inverter with converter assembly.
Tech Tips
For the removal and installation procedures related to the generator cable and motor cable, Click here for LHD, Click here for RHD).
Check MG2 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
Tech Tips
If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | ||||||||||||
|
||||||||||||
| RHD | ||||||||||||
|
Tech Tips
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68° F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (° C)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
Check the connection condition of the generator resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
Note
If the terminals connect poorly, are damaged, or contain water or foreign matter, repair or replace the wire harness or connector.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
Check the connection condition of the motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
Note
If the terminals connect poorly, are damaged, or contain water or foreign matter, repair or replace the wire harness or connector.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK QUANTITY OF HV COOLANT
Check the coolant level in the inverter reserve tank.
Check for coolant leaks.
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Tech Tips
After repairing the coolant leaks and adding coolant, perform the "Activate the Water Pump" active test (HV ECU active test item) and the "Control the Electric Cooling Fan" active test (Engine ECU active test item) and make sure that there are no malfunctions.
| B |
|
ADD HV COOLANT |
| C |
|
CHECK FOR COOLANT LEAKS AND ADD COOLANT |
| A |
|
CHECK COOLANT HOSE
Check if the hoses of the cooling system are kinked or clogged.
| NG |
|
CORRECT THE PROBLEM |
| OK |
|
PERFORM ACTIVE TEST USING INTELLIGENT TESTER (WATER PUMP)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Perform the "Activate the Water Pump" active test for at least 1 minute.
Check that there are ripples in the coolant in the inverter reserve tank.
| OK |
|---|
| There are ripples in the coolant in the inverter reserve tank as long as the active test is being performed. |
Note
In addition to the active test, the water pump with motor and bracket assembly will also operate with the power switch on (READY). However, the water pump with motor and bracket assembly will operate at low speed for 20 seconds after the power switch is turned on (READY).
Tech Tips
The water pump with motor and bracket assembly will also operate in inspection mode.
| NG |
|
| OK |
|
PERFORM ACTIVE TEST USING INTELLIGENT TESTER (COOLING FAN)
Select the following menu items: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.
Perform the "Control the Electric Cooling Fan" active test.
| OK |
|---|
| The cooling fan rotates. |
| NG |
|
CHECK COOLING FAN SYSTEM Click here |
| OK |
|
INSPECT COOLING SYSTEM (FOR CLOGGING)
Drain the inverter coolant Click here.
Note
Do not reuse the drained coolant because it may contain foreign objects.
Tech Tips
Drain the inverter coolant with the inverter reserve tank cap installed.
Install the inverter reserve tank cap.
Remove the drain plug.
Disconnect end A of the No. 3 inverter cooling hose.
Note
Applied air pressure should be 59 kPa (0.6 kgf/cm2, 8.6 psi) or less.
Be careful when disconnecting the hose. Coolant may spill out of the hose.
Cover the pipe shown in the illustration with packing tape.
Using an air gun, apply air to the disconnected end of the hose to check for clogging in the coolant path.
Note
Be careful when applying air. Applying excessive air may cause coolant to overflow from the inverter reserve tank cap.
| OK |
|---|
| Coolant and air come out from the drain. |
Connect end A of the No. 3 inverter cooling hose and disconnect end B.
Cover the pipe shown in the illustration with packing tape.
Using an air gun, apply air to the disconnected end of the hose to check for clogging in the coolant path.
Note
Applied air pressure should be 59 kPa (0.6 kgf/cm2, 8.6 psi) or less.
Be careful when applying air. Applying excessive air may cause coolant to overflow from the inverter reserve tank cap.
| OK |
|---|
| Coolant and air come out from the drain. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
After this inspection, check for coolant leaks from the hose with the power switch on (READY).
Note
If leaks are found, replace the No. 3 inverter cooling hose and clamps.
| B |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here |
| C |
|
REPLACE MALFUNCTIONING PARTS |
| A |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here
CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
Check the connection condition of the generator resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
Note
If the terminals connect poorly, are damaged, or contain water or foreign matter, repair or replace the wire harness or connector.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY (MG ECU) - GENERATOR RESOLVER)
Disconnect the generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| RHD | |||||||||||||||||||||
|
| Standard resistance (Check for short) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| RHD | |||||||||||||||||||||
|
Tech Tips
The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transmission assembly.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here
CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
Check the connection condition of the motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
Note
If the terminals connect poorly, are damaged, or contain water or foreign matter, repair or replace the wire harness or connector.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY (MG ECU) - MOTOR RESOLVER)
Disconnect the motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| RHD | |||||||||||||||||||||
|
| Standard resistance (Check for short) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LHD | |||||||||||||||||||||
|
|||||||||||||||||||||
| RHD | |||||||||||||||||||||
|
Tech Tips
The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transmission assembly.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
Remove the hybrid vehicle transmission assembly Click here.
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m {82 kgf*cm, 71 in.*lbf} |
Note
Make sure that the tightening torque of the bolts is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Check for arc marks at the bolts for the generator cable.
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK GENERATOR CABLE
Remove the generator cable from the hybrid vehicle transmission assembly. Click here
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE GENERATOR CABLE Click here |
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
Remove the hybrid vehicle transmission assembly. Click here
Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m {82 kgf*cm, 71 in.*lbf} |
Note
Make sure that the tightening torque of the bolts is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Check for arc marks at the bolts for the motor cable.
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK MOTOR CABLE
Remove the motor cable from the hybrid vehicle transmission assembly. Click here
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE MOTOR CABLE Click here |
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here
PERFORM ACTIVE TEST USING INTELLIGENT TESTER (WATER PUMP)
Connect the intelligent tester to the DLC3.
Compress the inlet hose for the water pump with motor and bracket assembly several times.
Turn the power switch on (IG) again.
Select the following menu items: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Perform the "Activate the Water Pump" active test for at least 1 minute.
Check that there are ripples in the coolant in the inverter reserve tank.
| OK |
|---|
| There are ripples in the coolant in the inverter reserve tank as long as the active test is being performed. |
Note
In addition to the active test, the water pump with motor and bracket assembly will also operate with the power switch on (READY). However, the water pump with motor and bracket assembly will operate at low speed for 20 seconds after the power switch is turned on (READY).
Tech Tips
The water pump with motor and bracket assembly will also operate in inspection mode.
| NG |
|
| OK |
|
ADD HV COOLANT
CHECK FUSE (INV W/P)
Check if there is an open circuit in the fuse (INV W/P) in the engine room No. 2 relay block.
| OK |
|---|
| There is no open circuit in the fuse (INV W/P). |
Tech Tips
If the result is NG, replace the fuse (INV W/P) with a new one.
| NG |
|
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY CONNECTOR)
Check the connection of the water pump with motor and bracket assembly connector.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)
Check the connections of the hybrid vehicle control ECU connectors.
| OK |
|---|
| The connectors are connected securely and there are no contact problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK HARNESS AND CONNECTOR (WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY)
Disconnect connector A78 from the hybrid vehicle control ECU.
Remove the fuse (INV W/P) from the engine room No. 2 relay block.
Disconnect the water pump with motor and bracket assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard resistance (Check for short) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY
Apply 12 V to terminal 2 of the INV W/P fuse holder of the engine room No. 2 relay block and check that the water pump operates.
| OK |
|---|
| The water pump operates. |
| NG |
|
REPLACE WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY Click here |
| OK |
|
REPLACE HYBRID VEHICLE CONTROL ECU Click here
CHECK CONNECTOR CONNECTION CONDITION (WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY CONNECTOR)
Check the connection of the water pump with motor and bracket assembly connector.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)
Check the connections of the hybrid vehicle control ECU connectors.
| OK |
|---|
| The connectors are connected securely and there are no contact problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK HARNESS AND CONNECTOR (WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY)
Disconnect connector A78 from the hybrid vehicle control ECU.
Remove the fuse (INV W/P) from the engine room No. 2 relay block.
Disconnect the water pump with motor and bracket assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard resistance (Check for short) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY
Apply 12 V to terminal 2 of the INV W/P fuse holder of the engine room No. 2 relay block and check that the water pump operates.
| OK |
|---|
| The water pump operates. |
| NG |
|
REPLACE WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY Click here |
| OK |
|
REPLACE HYBRID VEHICLE CONTROL ECU Click here