GENERATOR REMOVAL


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work Click here.

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  3. REMOVE V-RIBBED BELT

    Click here.

  4. REMOVE GENERATOR ASSEMBLY


    1. A01HQBK

      Disconnect the generator connector.

    2. Remove the terminal cap.

    3. Remove the nut and disconnect the generator wire.

    4. Remove the bolt and wire harness clamp bracket.

    5. A01HN50

      Remove the 2 bolts and generator.