AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P0778

DTC Code DTC Name
P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)

DESCRIPTION

Shifting from 1st to 5th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, SL3, S4 and SR which are controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (Fail safe function).

DTC No. DTC Detection Condition Trouble Area
P0778

ECM checks for an open or short circuit in shift solenoid valves SL2 (1-trip detection logic)

Hybrid IC for solenoid indicates fail.


  • Open or short in shift solenoid valve SL2 circuit

  • Shift solenoid valve SL2

  • ECM

MONITOR DESCRIPTION

The ECM commands gear shifts by turning the shift solenoid valves "ON/OFF". When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL, and stores the DTC. And the ECM performs the fail-safe function and turns the other normal shift solenoid valves "ON/OFF" (In case of an open or short circuit, the ECM stops sending current to the circuit.) Click here.

WIRING DIAGRAM

A017FXEE64

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SL2)


    1. A017EZRE52

      Disconnect the transmission wire connector from the transaxle.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      5 (SL2+) - 12 (SL2-) 20°C (68°F) 5.0 to 5.6 Ω
    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for short)
      Tester Connection Condition Specified Condition
      5 (SL2+) - Body ground Always 10 kΩ or higher
      12 (SL2-) - Body ground Always 10 kΩ or higher

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. A017CYDE14

      Connect the transmission wire connector to the transaxle.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      B2-15 (SL2+) - B2-14 (SL2-) 20°C (68°F) 5.0 to 5.6 Ω
    4. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for short)
      Tester Connection Condition Specified Condition
      B2-15 (SL2+) - Body ground Always 10 kΩ or higher
      B2-14 (SL2-) - Body ground

    NG
    OK
  3. INSPECT SHIFT SOLENOID VALVE (SL2)


    1. A017EGEE89

      Remove the shift solenoid valve SL2.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

      OK
      The solenoid makes an operating sound.

    NG
    OK