MASS AIR FLOW METER INSTALLATION


  1. INSTALL MASS AIR FLOW METER

    A01BAJX

    1. Install the mass air flow meter with the 2 screws.

  2. INSTALL AIR CLEANER ASSEMBLY


    1. Connect the mass air flow meter connector.

    2. A01BEW8

      Install the air cleaner assembly with the 4 bolts.

      Torque:
      18 N*m  { 180 kgf*cm, 13 ft.*lbf }
    3. A01BBMD

      Tighten the No. 1 air inlet hose clamp.

  3. INSTALL FRONT BUMPER

  4. INSTALL STEP PLATE COVER RH

  5. INSTALL STEP PLATE COVER LH

  6. INSTALL RADIATOR GRILLE

  7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Torque:
    5.4 N*m  { 55 kgf*cm, 48 in.*lbf }
  8. PERFORM INITIALIZATION


    1. Perform initialization procedures Click here.

      Note

      Certain systems need to be initialized after reconnecting the cable to the negative (-) battery terminal.