CAUTION / NOTICE / HINT
Tech Tips
Use the same procedure for RHD and LHD vehicles.
The procedure listed below is for LHD vehicles.
PROCEDURE
INSTALL HOOD LOCK CONTROL ASSEMBLY
|
Install in this Direction |
Install the hood lock control assembly.
INSTALL HOOD LOCK CONTROL CABLE COVER RH (for RHD)
INSTALL HOOD LOCK ASSEMBLY
INSTALL POP UP HOOD LIFTER ASSEMBLY LH
Check that the power switch is off.
Check that the cable is disconnected from the negative (-) auxiliary battery terminal.
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the pedestrian protection system.
If the pop up hood lifter deploys for any reason, it may cause a serious accident.
Pass the pop up hood lifter assembly LH under the air conditioning hose as shown in the illustration.
Attach the hook to set the pop up hood lifter assembly LH.
Install the 3 bolts.
Connect the pop up hood lifter connector.
Before connecting the connector, check that the position of the housing lock is correct as shown in the illustration.
| *a | Correct | *b | Incorrect |
| *c | CPA | *d | Housing |
| *a | Housing Lock |
| *b | CPA |
| *c | CPA Upper Part |
|
Connect in this Direction |
While holding the CPA be sure to engage the connectors until they are locked and check that the CPA is in its original position (when locking, make sure that a click sound can be heard).
Note
Do not push down the upper part of the CPA shown in the illustration when connecting the pop up hood lifter connector.
INSTALL POP UP HOOD LIFTER ASSEMBLY RH
Check that the power switch is off.
Check that the cable is disconnected from the negative (-) auxiliary battery terminal.
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the pedestrian protection system.
If the pop up hood lifter deploys for any reason, it may cause a serious accident.
|
Attach Hood Lock Control Assembly Cable Clamp in this Direction |
|
Connect Hood Lock Control Assembly Cable End in this Direction |
Connect the hood lock control cable end.
Connect the hood lock control cable clamp.
Attach the hook to set the pop up hood lifter assembly RH.
Install the 3 bolts.
Connect the pop up hood lifter connector.
Before connecting the connector, check that the position of the housing lock is correct as shown in the illustration.
| *a | Correct | *b | Incorrect |
| *c | CPA | *d | Housing |
| *a | Housing Lock |
| *b | CPA |
| *c | CPA Upper Part |
|
Connect in this Direction |
While holding the CPA be sure to engage the connectors until they are locked and check that the CPA is in its original position (when locking, make sure that a click sound can be heard).
Note
Do not push down the upper part of the CPA shown in the illustration when connecting the pop up hood lifter connector.
INSTALL FRONT AIRBAG SENSOR LH (for LH Side)
INSTALL FRONT AIRBAG SENSOR RH (for RH Side)
Tech Tips
Use the same procedure for the LH side.
CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
INSTALL LUGGAGE COMPARTMENT MAT SUB-ASSEMBLY
PERFORM DIAGNOSTIC SYSTEM CHECK
CHECK SRS WARNING LIGHT
PERFORM SYSTEM CALIBRATION
ADJUST HEADLIGHT AIMING