| DTC Code | DTC Name |
|---|---|
| P1C641F | Generator Control Module Circuit Intermittent |
| P1CAC49 | Generator Position Sensor Internal Electronic Failure |
| P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect |
DESCRIPTION
The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors its internal operation and detects malfunctions.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P1C641F | Generator Control Module Circuit Intermittent | Excitation signal (REF signal) for resolver angle detection cycle malfunction detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored. (1 trip detection logic) |
|
Does not come on | Master Warning Light: Does not come on |
| P1CAC49 | Generator Position Sensor Internal Electronic Failure | Generator resolver angle malfunction: The difference between the resolver angle for control and estimated resolver angle exceeds the allowable limit. (1 trip detection logic) |
|
Comes on | Master Warning Light: Comes on |
| P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | Resolver REF signal cycle malfunction: Excitation signal (REF signal) for resolver angle detection cycle malfunction (1 trip detection logic) |
|
Comes on | Master Warning Light: Comes on |
| DTC No. | Data List |
|---|---|
| P1CAC49 | Generator Revolution |
| P1CAF38 |
CONFIRMATION DRIVING PATTERN
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
With power switch on (IG) and wait for 5 seconds or more.*
*: Lightly wiggle the connectors and wire harnesses up and down and right and left.
Turn the power switch on (READY) with park (P) selected and wait for 5 seconds or more.
Depress the accelerator pedal of the vehicle with the engine stopped and park (P) selected to start the engine.
Keep the engine running for 5 seconds or more.
Select drive (D) and drive the vehicle forward for 5 m (16 ft.) or more.
Select reverse (R) and drive the vehicle backward for 5 m (16 ft.) or more.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
WIRING DIAGRAM
Refer to the wiring diagram for the Motor Resolver Circuit.
Refer to the wiring diagram for the Generator Resolver Circuit.
CAUTION / NOTICE / HINT
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
If the problem symptom cannot be reproduced, performing a road test on a road on which the vehicle tends to vibrate will make it easier to reproduce the symptom.
If the resolver is malfunctioning, the vehicle may not drive smoothly.
When inspecting the connectors, if it is difficult to judge if a connector was disconnected, deformed or improperly secured, disconnect and reconnect the connector and then check for DTCs again. Check if the same DTC is output. If the same DTC is not output, improper connection of connectors is suspected.
As a malfunction detection threshold may be exceeded when performing the vibration or heat connector inspections, make sure to perform the following inspection to check that the DTC was not stored due to the malfunction of a part.
PROCEDURE
CHECK DTC OUTPUT (MOTOR GENERATOR)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
Check for DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| Relevant DTC | |
|---|---|
| P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold |
| P0C6413 | Generator Position Sensor Circuit "A" Circuit Open |
| P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C6913 | Generator Position Sensor Circuit "B" Circuit Open |
| P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold |
Turn the power switch off.
GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM)Click here
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD | *B | for RHD |
Check the connection condition of the low voltage connectors of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and the connector for water and foreign matter.
Before disconnecting the connector, confirm that it is properly connected by checking that the claws of the lock levers are engaged and that the connector cannot be pulled off.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
When connecting the connector, connect it with the lock levers raised. Rotate each lock lever downward and make sure that the connector is securely connected. When a lock lever is fully lowered, a click will be heard as its claw engages. After the click is heard, pull up on the connector to confirm that it is securely connected.
CONNECT SECURELY
REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK GENERATOR RESOLVER CIRCUIT
| Result | ||
|---|---|---|
|
CHECK MOTOR RESOLVER CIRCUIT
If the "Motor Resolver Circuit" inspection results are normal, perform the next step.
| Result | ||
|---|---|---|
|
REPLACE INVERTER WITH CONVERTER ASSEMBLYClick here