MOTOR GENERATOR CONTROL SYSTEM, Diagnostic DTC:P1C5312, P1C5314, P1C531F, P1C5812, P1C5814, P1C581F

Click here
Click here
DTC Code DTC Name
P1C5312 Generator Phase V Current Sensor "B" Circuit Short to Battery
P1C5314 Generator Phase V Current Sensor "B" Circuit Short to Ground or Open
P1C531F Generator Phase V Current Sensor "B" Circuit Intermittent
P1C5812 Generator Phase W Current Sensor "B" Circuit Short to Battery
P1C5814 Generator Phase W Current Sensor "B" Circuit Short to Ground or Open
P1C581F Generator Phase W Current Sensor "B" Circuit Intermittent
Click here

DTC SUMMARY


Click here
  1. MALFUNCTION DESCRIPTION

    These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:


    • Internal inverter malfunction
    • Inverter with converter assembly internal circuit malfunction


    • Inverter low-voltage circuit malfunction
    • The connectors are not connected properly

Click here

DESCRIPTION

The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors the generator inverter current sensor. These DTCs indicate the malfunction of current sensors and do not indicate a malfunction of the high-voltage system.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P1C5312 Generator Phase V Current Sensor "B" Circuit Short to Battery

Malfunction in generator inverter current sensor (phase V sub sensor)

(Short to +B)

(1 trip detection logic)


  • Inverter with converter assembly

  • Wire harness or connector

Comes on

Master Warning Light:

Comes on

P1C5314 Generator Phase V Current Sensor "B" Circuit Short to Ground or Open

Malfunction in generator inverter current sensor (phase V sub sensor)

(Open or short to ground)

(1 trip detection logic)


  • Inverter with converter assembly

  • Wire harness or connector

Comes on

Master Warning Light:

Comes on

P1C531F Generator Phase V Current Sensor "B" Circuit Intermittent

Short to +B, open or short to ground detected in generator inverter current sensor (phase V sub sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.

(1 trip detection logic)


  • Inverter with converter assembly

  • Wire harness or connector

Does not come on

Master Warning Light:

Does not come on

P1C5812 Generator Phase W Current Sensor "B" Circuit Short to Battery

Malfunction in generator inverter current sensor (phase W sub sensor)

(Short to +B)

(1 trip detection logic)


  • Inverter with converter assembly

  • Wire harness or connector

Comes on

Master Warning Light:

Comes on

P1C5814 Generator Phase W Current Sensor "B" Circuit Short to Ground or Open

Malfunction in generator inverter current sensor (phase W sub sensor)

(Open or short to ground)

(1 trip detection logic)


  • Inverter with converter assembly

  • Wire harness or connector

Comes on

Master Warning Light:

Comes on

P1C581F Generator Phase W Current Sensor "B" Circuit Intermittent

Short to +B, open or short to ground detected in generator inverter current sensor (phase W sub sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.

(1 trip detection logic)


  • Inverter with converter assembly

  • Wire harness or connector

Does not come on

Master Warning Light:

Does not come on

Click here

CONFIRMATION DRIVING PATTERN

Tip:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click here


  1. Connect the GTS to the DLC3.

  2. Turn the power switch on (IG) and turn the GTS on.

  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

  4. Turn the power switch off and wait for 2 minutes or more.

  5. Turn the power switch on (IG) and turn the GTS on.

  6. With power switch on (IG) and wait for 5 seconds or more.

  7. Turn the power switch on (READY) with park (P) selected and wait for 5 seconds or more.

  8. Depress the accelerator pedal of the vehicle with the engine stopped and park (P) selected to start the engine.

  9. Select drive (D) and drive the vehicle forward for 5 m (16 ft.) or more.

  10. Select reverse (R) and drive the vehicle backward for 5 m (16 ft.) or more.

  11. Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

  12. Check the DTC judgment result.

    Tip:
    • If the judgment result shows NORMAL, the system is normal.

    • If the judgment result shows ABNORMAL, the system has a malfunction.

    • If the judgment result shows INCOMPLETE, perform driving pattern again.

Click here

CAUTION / NOTICE / HINT

CAUTION:

  • B004STG

    Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.


    • Inspecting the high-voltage system

    • Disconnecting the low voltage connector of the inverter with converter assembly

    • Disconnecting the low voltage connector of the HV battery

  • B004Y5N

    To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

  • B004SX1

    After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • B004W3JC06
    *a Without waiting for 10 minutes

    After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    Click here

    Tip:

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click here

Click here

PROCEDURE


  1. Click here

    CHECK DTC OUTPUT (MOTOR GENERATOR)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Motor Generator / Trouble Codes.

    4. Check for DTCs.


      1. Powertrain > Motor Generator > Trouble Codes


      Result
      Result Proceed to
      P1C5312, P1C5314, P1C531F, P1C5812, P1C5814 or P1C581F only is output, or DTCs except the ones in the table below are also output. A
      Any of the following DTCs including pending DTCs are also output. B
      Malfunction Content Relevant DTC
      Power source circuit malfunction P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
      P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range
      System malfunction P0A7A73 Generator Inverter Actuator Stuck Closed
      Tip:
      • P1C5312, P1C5314, P1C531F, P1C5812, P1C5814 or P1C581F may be output as a result of the malfunction indicated by the DTCs above.


        1. The chart above is listed in inspection order of priority.

        2. Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)

    5. Turn the power switch off.


  2. Click here

    CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    Result
    Result Proceed to
    OK A
    NG (The connector is not connected securely.) B
    NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C
    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note:

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B004SKUC01
      *A for LHD *B for RHD

      Check the connection condition of the low voltage connectors of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and the connector for water and foreign matter.

      Click here

      Note:

      Before disconnecting the connector, confirm that it is properly connected by checking that the claws of the lock levers are engaged and that the connector cannot be pulled off.

      OK
      - The connector is connected securely.
      - The terminals are not deformed and are connected securely.
      - No water or foreign matter in the connector.
      Result
      Result Proceed to
      OK A
      NG (The connector is not connected securely.) B
      NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C
      Tip:

      When connecting the connector, connect it with the lock levers raised. Rotate each lock lever downward and make sure that the connector is securely connected. When a lock lever is fully lowered, a click will be heard as its claw engages. After the click is heard, pull up on the connector to confirm that it is securely connected.


    • A

      REPLACE INVERTER WITH CONVERTER ASSEMBLYClick here

    • B

      CONNECT SECURELY

    • C

      REPAIR OR REPLACE HARNESS OR CONNECTOR