| DTC Code | DTC Name |
|---|---|
| B1423 | Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure |
DESCRIPTION
This DTC is stored if refrigerant pressure on the high pressure side is extremely low (176 kPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPa (30.8 kgf/cm2, 439 psi) or more). The air conditioner pressure sensor, which is installed to the high pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1423 | Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure |
|
|
- |
WIRING DIAGRAM
| *a | Air Conditioner Pressure Sensor |
| *b | Air Conditioning Amplifier Assembly |
CAUTION / NOTICE / HINT
Tech Tips
If DTC B1423 and B14B8 are output at the same time, troubleshoot for DTC B14B8 first.
PROCEDURE
CHECK FOR DTC
Check for DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
GO TO DTC B14B8 Click here |
| A |
|
PERFORM REFRIGERANT SHORTAGE CHECK
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
| Tester Display |
|---|
| Refrigerant Gas Volume Check |
Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.
| Item | Condition |
|---|---|
| A/C switch | On |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| Blower speed | HI |
*: If the ambient temperature is not within the range shown, do not perform this check.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| OK |
|---|
| "Refrigerant correct" is displayed on GTS. |
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR AIR CONDITIONING SYSTEM LEAK Click here |
| OK |
|
CHECK REFRIGERANT PRESSURE
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.6 kPaG (gauge) Max.: 3294.3 kPaG (gauge) |
Actual refrigerant pressure displayed |
|
| Tester Display |
|---|
| Regulator Pressure Sensor |
Install a manifold gauge set.
Read the manifold gauge set with the following conditions met.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
| Standard Pressure |
|---|
| Low pressure side |
| 150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi) |
| High pressure side |
| 1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi) |
Compare the values displayed in the Data List and on the manifold gauge set.
| OK |
|---|
| The values displayed in the Data List and on the manifold gauge set match. |
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT) Click here |
| OK |
|
CHECK REFRIGERANT HIGH PRESSURE HISTORY
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Refrigerant High Pressure History | Refrigerant high pressure history | Min.: 0 Max.: 255 |
Number of times refrigerant high pressure history stored displayed | - |
| Tester Display |
|---|
| Refrigerant High Pressure History |
| Result | ||||||
|---|---|---|---|---|---|---|
|
| A |
|
INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET Click here |
| B |
|
INSPECT COOLING FAN SYSTEM
Check if the cooling fan operates normally.
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO COOLING FAN SYSTEM for 2AR-FE: Click here |
| OK |
|
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
| Result | ||
|---|---|---|
|
| NEXT |
|
PERFORM REFRIGERANT HIGH PRESSURE HISTORY CLEAR
Clear the refrigerant high pressure history stored in the air conditioning amplifier assembly.
| Result | ||
|---|---|---|
|
| NEXT |
|
END |
CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
| *a | Front view of wire harness connector (to Air Conditioner Pressure Sensor) |
Disconnect the A18 air conditioner pressure sensor connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - BODY GROUND)
| *a | Front view of wire harness connector (to Air Conditioner Pressure Sensor) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Disconnect the K55 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
Measure the voltage with the following conditions met.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
Note
If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), a fail-safe function will stop compressor operation. In this case, make sure to measure the voltage before the fail-safe function operates.
It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
Tech Tips
When the ambient air temperature is low(below -1.5°C (29.3°F)), the compressor with pulley will be stopped, due to inputs of the thermistor assembly and No. 1 cooler thermistor, to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
*: While sensor voltage is 5 V.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.6 kPaG (gauge) Max.: 3294.3 kPaG (gauge) |
Actual refrigerant pressure displayed |
|
| Tester Display |
|---|
| Regulator Pressure Sensor |
| OK |
|---|
| The voltage and value displayed in the Data List change. |
| Result | |||||||
|---|---|---|---|---|---|---|---|
|
| A |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| B |
|
REPLACE AIR CONDITIONER PRESSURE SENSOR Click here |
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Disconnect the K55 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Disconnect the K55 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
REPAIR AIR CONDITIONING SYSTEM LEAK
Identify the area where refrigerant is leaking from.
Repair the identified area of the air conditioning system.
Evacuate the air conditioning system.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHARGE SYSTEM WITH REFRIGERANT Click here |