| DTC Code | DTC Name |
|---|---|
| B1423 | Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure |
DESCRIPTION
This DTC is stored if refrigerant pressure on the high pressure side is extremely low (176 kPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPa (30.8 kgf/cm2, 439 psi) or more). The air conditioner pressure sensor, which is installed to the high pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1423 | Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure |
|
|
- |
WIRING DIAGRAM
| *a | Air Conditioner Pressure Sensor |
| *b | Air Conditioning Amplifier Assembly |
CAUTION / NOTICE / HINT
Tech Tips
If DTC B1423 and B14B8 are output at the same time, troubleshoot for DTC B14B8 first.
PROCEDURE
PERFORM REFRIGERANT SHORTAGE CHECK
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
| Tester Display |
|---|
| Refrigerant Gas Volume Check |
Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.
| Item | Condition |
|---|---|
| A/C switch | On |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| Blower speed | HI |
*: If the ambient temperature is not within the range shown, do not perform this check.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| OK |
|---|
| "Refrigerant correct" is displayed on the GTS. |
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR AIR CONDITIONING SYSTEM LEAK Click here |
| OK |
|
CHECK REFRIGERANT PRESSURE
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.6 kPaG (gauge) Max.: 3294.3 kPaG (gauge) |
Actual refrigerant pressure displayed |
|
| Tester Display |
|---|
| Regulator Pressure Sensor |
Install a manifold gauge set.
Read the manifold gauge set with the following conditions met.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
| Standard Pressure |
|---|
| Low pressure side |
| 150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi) |
| High pressure side |
| 1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi) |
Compare the values displayed in the Data List and on the manifold gauge set.
| OK |
|---|
| The values displayed in the Data List and on the manifold gauge set match. |
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT) Click here |
| OK |
|
CHECK REFRIGERANT HIGH PRESSURE HISTORY
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Refrigerant High Pressure History | Refrigerant high pressure history | Min.: 0 Max.: 255 |
Number of times refrigerant high pressure history stored displayed | - |
| Tester Display |
|---|
| Refrigerant High Pressure History |
| Result | ||||||
|---|---|---|---|---|---|---|
|
| A |
|
INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET Click here |
| B |
|
INSPECT COOLING FAN SYSTEM
Check if the cooling fan operates normally.
for 2AR-FE: Click here
for A25A-FKS: Click here
for 2GR-FKS: Click here
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO COOLING FAN SYSTEM for 2AR-FE: Click here |
| OK |
|
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
| Result | ||
|---|---|---|
|
| NEXT |
|
PERFORM REFRIGERANT HIGH PRESSURE HISTORY CLEAR
Clear the refrigerant high pressure history stored in the air conditioning amplifier assembly.
| Result | ||
|---|---|---|
|
| NEXT |
|
END |
CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
| *a | Front view of wire harness connector (to Air Conditioner Pressure Sensor) |
Disconnect the A18 air conditioner pressure sensor connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - BODY GROUND)
| *a | Front view of wire harness connector (to Air Conditioner Pressure Sensor) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Disconnect the K55 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
Measure the voltage with the following conditions met.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
Note
If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), a fail-safe function will stop compressor operation. In this case, make sure to measure the voltage before the fail-safe function operates.
It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
Tech Tips
When the ambient air temperature is low(below -1.5°C (29.3°F)), the compressor with pulley will be stopped, due to inputs of the thermistor assembly and No. 1 cooler thermistor, to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
*: While sensor voltage is 5 V.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.6 kPaG (gauge) Max.: 3294.3 kPaG (gauge) |
Actual refrigerant pressure displayed |
|
| Tester Display |
|---|
| Regulator Pressure Sensor |
| OK |
|---|
| The voltage and value displayed in the Data List change. |
| Result | |||||||
|---|---|---|---|---|---|---|---|
|
| A |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| B |
|
REPLACE AIR CONDITIONER PRESSURE SENSOR Click here |
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Disconnect the K55 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Disconnect the K55 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
REPAIR AIR CONDITIONING SYSTEM LEAK
Identify the area where refrigerant is leaking from.
Repair the identified area of the air conditioning system.
Evacuate the air conditioning system.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHARGE SYSTEM WITH REFRIGERANT Click here |