HEATED OXYGEN SENSOR INSTALLATION

PROCEDURE


  1. INSTALL HEATED OXYGEN SENSOR (for Bank 2)

    Tech Tips

    Perform "Inspection After Repair" after replacing a heated oxygen sensor. (w/ Canister Pump Module)

    Click here


    1. B005L1TC01
      *a Torque Wrench Fulcrum Length

      Using SST, install the heated oxygen sensor to the front exhaust pipe assembly.

      SST
      09224-00011
      Torque:
      Specified tightening torque
      44 N*m  { 449 kgf*cm, 32 ft.*lbf }

      Note

      If the heated oxygen sensor has been struck or dropped, replace it.

      Tech Tips


      • Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.

        Click here

      • When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)):

        39 N*m (398 kgf*cm, 29 ft.*lbf)

  2. INSTALL FRONT EXHAUST PIPE ASSEMBLY

    Click here

  3. INSTALL HEATED OXYGEN SENSOR (for Bank 1)

    Tech Tips

    Perform "Inspection After Repair" after replacing a heated oxygen sensor. (w/ Canister Pump Module)

    Click here


    1. B005LHUC01
      *a Torque Wrench Fulcrum Length

      Using SST, install the heated oxygen sensor to the front No. 3 exhaust pipe sub-assembly.

      SST
      09224-00011
      Torque:
      Specified tightening torque
      44 N*m  { 449 kgf*cm, 32 ft.*lbf }

      Note

      If the heated oxygen sensor has been struck or dropped, replace it.

      Tech Tips


      • Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.

        Click here

      • When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)):

        39 N*m (398 kgf*cm, 29 ft.*lbf)

    2. B005OJQC01
      *1 Wire Harness Clamp Bracket
      *a Left of Vehicle
      *b 180°

      Install the wire harness clamp bracket to the heated oxygen sensor.

      Tech Tips

      Make sure the direction of the wire harness clamp bracket is as shown in the illustration.

  4. INSPECT FOR EXHAUST GAS LEAK

    Click here

  5. INSTALL FRONT FLOOR COVER LH

    Click here

  6. PERFORM INITIALIZATION (w/ Canister Pump Module)


    1. Perform "Inspection After Repair" after replacing a heated oxygen sensor.

      Click here