COMBINATION METER REMOVAL

CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the combination meter removal/installation are shown below.

Necessary Procedure After Parts Removed/Installed/Replaced
Replacement Part or Procedure Necessary Procedure Effect/Inoperative when not Performed Link
Disconnect cable from negative battery terminal Memorize steering angle neutral point Parking assist monitor system

Click here

LKA/LDA system

Click here

Pre-crash safety system
Adaptive high beam system
Reset power trunk lid Power trunk lid system

Click here

Tech Tips


  • Use the same procedure for RHD and LHD vehicles.

  • The procedure listed below is for LHD vehicles.

PROCEDURE


  1. PRECAUTION

    Note

    After turning the engine switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

    Click here

  2. CUSTOMIZE POWER TILT AND POWER TELESCOPIC STEERING COLUMN SYSTEM SETTINGS

    Click here

  3. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Click here

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  4. REMOVE NO. 1 INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY

    Click here

  5. REMOVE INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY

    Click here

  6. REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY

    Click here

  7. REMOVE COMBINATION METER ASSEMBLY


    1. B002EN5

      Remove the 4 screws.

    2. B002EV9

      Disengage the clamp.

    3. Disconnect the 3 connectors to remove the combination meter assembly.