GENERATOR REMOVAL

PROCEDURE


  1. PRECAUTION

    Note

    After turning the engine switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work Click here.

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  3. REMOVE RADIATOR ASSEMBLY

    Click here

  4. REMOVE V-BANK COVER SUB-ASSEMBLY

    Click here

  5. REMOVE V-RIBBED BELT

    Click here

  6. REMOVE GENERATOR ASSEMBLY


    1. B001OJY

      Disconnect the connector.

    2. Remove the cap.

    3. Remove the nut and disconnect the wire harness.

    4. Remove the bolt and disconnect the wire harness clamp.

    5. B001O71

      Remove the 2 bolts.

    6. Disconnect the wire harness clamp and remove the generator bracket.

    7. B001NMD

      Remove the 2 bolts and generator assembly.